Add instructions for electricity export (return to grid)
Browse files Browse the repository at this point in the history
  • Loading branch information
gcoan authored Dec 23, 2024
1 parent e888b78 commit a82360f
Showing 1 changed file with 38 additions and 17 deletions.
55 changes: 38 additions & 17 deletions _docs/setup/energy_dashboard.md
Original file line number Diff line number Diff line change
@@ -1,10 +1,10 @@
# Energy Dashboard

## Current Consumption
## Current Consumption & Return

### For Electricity
### For Electricity Consumption (Grid Import)

You can only record current (i.e. today's) consumption in the Energy dashboard if you have a way of measuring live consumption in your home.
You can only record current (i.e. today's) consumption in the Energy dashboard if you have a way of measuring live grid import consumption in your home.

#### Octopus Home Mini

Expand All @@ -27,13 +27,28 @@ If you don't have an Octopus Home mini you may have another way to get live or n

Do be aware that as you are not directly capturing the smart meter readings in Home Assistant the consumption does not include the standing charge and there will always be a small measurement difference from what Octopus energy say you have used, but in practice the difference is likely to be quite small.


The energy dashboard can accept sensors that either track today's usage or total for all time usage. Its recommended that 'total' sensors are used as this gets around problems with 'today' sensors not precisely resetting at midnight and causing big spikes in the dashboard data.

1. Identify a sensor that is measuring your grid import. e.g. for a Hildebrand Glow it could be `sensor.smart_meter_electricity_energy_import`; a Shelly EM will be `sensor.<EM channel name>_energy_total`; for a GivEnergy inverter using the GivTCP integration it will be `sensor.givtcp_XXyywwXnnn_import_energy_total_kwh`
2. Then add the consumption information to the Energy dashboard in a similar way to the steps for Octopus Home Mini above, but for step 3, `consumed energy`, you want the existing import sensor you have identified, and for step 4, choose `Use an entity with current price` and the entity is `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_current_rate`

### For Gas
### For Electricity Return to Grid (Grid Export)

You can only record current (i.e. today's) grid return in the Energy dashboard if you have a way of measuring live grid export consumption in your home, and unfortunately the Octopus Home Mini does not record this.

For current consumption to appear in the Energy dashboard you therefore must have an alternative way to get live or near-live daily grid return data into Home Assistant such as a Hildebrand Glow In Home Display, an Energy CT Clamp such as the Shelly EM on the incoming supply cable, or your existing Solar/Battery inverter may have a sensor that provides Grid export information that you can use in the Energy dashboard.

Do be aware that as you are not directly capturing the smart meter grid return readings in Home Assistant there could be a small measurement difference from what Octopus energy say you have exported, but in practice the difference is likely to be quite small.

The energy dashboard can accept sensors that either track today's usage or total for all time usage. Its recommended that 'total' sensors are used as this gets around problems with 'today' sensors not precisely resetting at midnight and causing big spikes in the dashboard data.

1. Identify a sensor that is measuring your grid export. e.g. for a Hildebrand Glow it could be `sensor.smart_meter_electricity_energy_export`; a Shelly EM will be `sensor.<EM channel name>_energy_returned`; for a GivEnergy inverter using the GivTCP integration it will be `sensor.givtcp_XXyywwXnnn_export_energy_total_kwh`
2. Go to your [energy dashboard configuration](https://my.home-assistant.io/redirect/config_energy/)
3. Click `Add Return` under `Electricity grid`
3. For `Energy returned to the grid` you want the sensor name identified in step 1
4. Choose the `Use an entity with current rate` option and the entity is `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_export_current_rate`

### For Gas Consumption

![HA modal gas example](../assets/current_consumption_gas.png){: style="height:500px"}

Expand Down Expand Up @@ -67,30 +82,36 @@ If none of the methods above for feeding Current Day Consumption information int

I'm still investigating having hourly breakdowns imported on the entity themselves rather than as external statistics, but currently in doing so it's still including the spikes on the day of retrieval. I've opened a [forum post](https://community.home-assistant.io/t/help-needed-around-importing-historic-statistics/567726) but awaiting answers.

### For Electricity

### For Electricity (Grid Import)

![HA modal electricity example](../assets/previous_consumption_electricity.png){: style="height:500px"}

1. Go to your [energy dashboard configuration](https://my.home-assistant.io/redirect/config_energy/)
2. Click `Add Consumption` under `Electricity Grid`
3. For `consumed energy` you want one of the following:
* **`octopus_energy:`**`electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption` - The total consumption reported by the meter for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption.**
* **`octopus_energy:`**`electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption_peak` - The total consumption reported by the meter during peak hours for the previous day. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption_peak.**
* **`octopus_energy:`**`electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption_off_peak` - The total consumption reported by the meter during off-peak hours for the previous day. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption_off_peak.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption` - The total consumption reported by the meter for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption_peak` - The total consumption reported by the meter during peak hours for the previous day. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption_peak.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_consumption_off_peak` - The total consumption reported by the meter during off-peak hours for the previous day. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.electricity_{{METER}}_{{MPAN}}_previous_accumulative_consumption_off_peak.**
4. For `Use an entity tracking the total costs` option you want one of the following:
* `octopus_energy:electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost` - The total cost for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost.**
* `octopus_energy:electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_peak` - The total cost for the previous day that applied during peak hours. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_peak.**
* `octopus_energy:electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_off_peak` - The total cost for the previous day that applied during off-peak hours. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_off_peak.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost` - The total cost for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_peak` - The total cost for the previous day that applied during peak hours. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_peak.**
* `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_off_peak` - The total cost for the previous day that applied during off-peak hours. This will only be populated if you're on a tariff with two available rates and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them). **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_previous_accumulative_cost_off_peak.**

### For Electricity Return to Grid (Grid Export)

1. Go to your [energy dashboard configuration](https://my.home-assistant.io/redirect/config_energy/)
2. Click `Add Return` under `Electricity grid`
3. For `Energy returned to the grid` you want to choose the sensor `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_export_previous_accumulative_consumption` - The total export reported by the meter for the previous day and is [disabled by default](../faq.md#there-are-entities-that-are-disabled-why-are-they-disabled-and-how-do-i-enable-them).
4. Choose the `Use an entity tracking the total received money` option and the entity is `sensor.octopus_energy_electricity_{{METER_SERIAL_NUMBER}}_{{MPAN_NUMBER}}_export_previous_accumulative_cost` - The total grid export for the previous day.

### For Gas
### For Gas Consumption

![HA modal gas example](../assets/previous_consumption_gas.png){: style="height:500px"}

1. Go to your [energy dashboard configuration](https://my.home-assistant.io/redirect/config_energy/)
2. Click `Add Gas Source` under `Gas Consumption`
3. For `consumed energy` you want one of the following
* `octopus_energy:gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption` - The total consumption reported by the meter for the previous day in m3. If your meter reports in m3, then this will be an accurate value reported by Octopus, otherwise it will be a calculated/estimated value. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption.**
* `octopus_energy:gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption_kwh` - The total consumption reported by the meter for the previous day in kwh. If your meter reports in kwh, then this will be an accurate value reported by Octopus, otherwise it will be a calculated/estimated value. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption_kwh.**
* `sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption` - The total consumption reported by the meter for the previous day in m3. If your meter reports in m3, then this will be an accurate value reported by Octopus, otherwise it will be a calculated/estimated value. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption.**
* `sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption_kwh` - The total consumption reported by the meter for the previous day in kwh. If your meter reports in kwh, then this will be an accurate value reported by Octopus, otherwise it will be a calculated/estimated value. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_consumption_kwh.**
1. For `Use an entity tracking the total costs` option you want the following
* `octopus_energy:gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_cost` - The total cost for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_cost.**
* `sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_cost` - The total cost for the previous day. **Please note the different name to the standard entity, do NOT choose sensor.octopus_energy_gas_{{METER_SERIAL_NUMBER}}_{{MPRN_NUMBER}}_previous_accumulative_cost.**

0 comments on commit a82360f