8 changes: 4 additions & 4 deletions src/BatteryStats.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -379,8 +379,8 @@ void VictronSmartShuntStats::updateFrom(VeDirectShuntController::veShuntStruct c
_modelName = shuntData.getPidAsString().data();
_chargeCycles = shuntData.H4;
_timeToGo = shuntData.TTG / 60;
_chargedEnergy = shuntData.H18 / 100;
_dischargedEnergy = shuntData.H17 / 100;
_chargedEnergy = static_cast<float>(shuntData.H18) / 100;
_dischargedEnergy = static_cast<float>(shuntData.H17) / 100;
_manufacturer = "Victron " + _modelName;
_temperature = shuntData.T;
_tempPresent = shuntData.tempPresent;
Expand All @@ -401,8 +401,8 @@ void VictronSmartShuntStats::getLiveViewData(JsonVariant& root) const {
// values go into the "Status" card of the web application
addLiveViewValue(root, "current", _current, "A", 1);
addLiveViewValue(root, "chargeCycles", _chargeCycles, "", 0);
addLiveViewValue(root, "chargedEnergy", _chargedEnergy, "KWh", 1);
addLiveViewValue(root, "dischargedEnergy", _dischargedEnergy, "KWh", 1);
addLiveViewValue(root, "chargedEnergy", _chargedEnergy, "kWh", 2);
addLiveViewValue(root, "dischargedEnergy", _dischargedEnergy, "kWh", 2);
if (_tempPresent) {
addLiveViewValue(root, "temperature", _temperature, "°C", 0);
}
Expand Down