Skip to content

kettenbach-it/FHEM-SMA-Speedwire

Repository files navigation

FHEM-SMA-Speedwire

Repository for FHEM-support of devices that use the "SMA Speedwire" protocol.

  • 77_SMAEM.pm: Support for SMA Energymeter, a bidirectional energy meter/counter
  • 76_SMAInverter.pm:
  • 77_SMASTP.pm: Support for SMA Sunny Tripower Inverter -> Deprecated. Please use 76_SMAInverter.pm

FHEM-SMAEM

FHEM-Module for the SMA Energy Meter, a bidirectional energy meter/counter used in photovoltaics.

Installation & Dependencies

This module requires:

  • Perl Module: IO::Socket::Multicast

On a Debian (based) system, these requirements can be fullfilled by:

  • apt-get install libio-socket-multicast-perl

Before you start using 77_SMAEM.pm, you should try the test programm smaem_test.pl. It will read data sent by the SMA-EM over multicast and will print it to the terminal.

Concerning multicast: as long as your FHEM-host is on the same layer2/3 subnet (LAN) as your SMA-EM, multicast will pretty much behave like broadcast and you have nothing to worry about. If the receiving host is behind on or more routers, you have to make sure, that those routers have multicast forwarding enabled and configured.

Beware: some cheap soho-switches in the 50 euro class pretend to work with multicast but inexplicably block random multicast groups. You either have to switch to a better switch or use a super simple one (10 Euro), which doesn't understand multicast at all and will just treat it as broadcast.

Once you get proper readings with smaem_test.pl, you can install 77_SMAEM.pm just by copying it to your FHEM-installation.

Setup

Once copied to four FHEM-installation folder ("/FHEM"), load the module with

reload 77_SMAEM

Usage

Then you can define your SMA-EM like this:

define <name> SMAEM;

"The attibut interval" defines the update interval. If not set, it defaults to 60s. Since the SMAEM sends updates once a second (firmware 1.02.04.R, March 2016), you can update the readings once a second by lowering the interval to 1, which is not recommended, since it puts FHEM under heavy load.

Example:

define DP11_SMAEM SMAEM
attr DP11_SMAEM alias SMA Energy Meter
attr DP11_SMAEM group Photovoltaik Anlage
attr DP11_SMAEM room Zähler
attr DP11_SMAEM interval 120
attr DP11_SMAEM powerCost 0.28
attr DP11_SMAEM feedinPrice 0.124
attr DP11_SMAEM icon measure_power
attr DP11_SMAEM stateFormat {sprintf("%.1f",ReadingsVal($name,"state",0))." W"}

define DP11_SMAEM_LOG FileLog ./log/DP11_SMAEM_LOG-%Y.log DP11_SMAEM|DP11_SMAEM:.*

Limitations

77_SMAEM.pm is in principle capable of supporting several SMA-EMs but it has not been tested. In case you have more than one SMA-EM, please contact me. Each reading of each SMA-EM will be uniquely named containg the serial of the SMA-EM it came from, so you can distinguish between different SMA-EM inside FHEM.

FHEM-SMAInverter

FHEM Support for SMA Inverters over "Speedwire" TCP/IP (=Ethernet) network. Tested on Sunny Tripower 6000TL-20, 10000TL-20 and Sunny Island 4.4 with Speedwire/Webconnect Piggyback.

Installation & Dependencies

This module requires:

  • Perl Module: IO::Socket::INET (apt-get install libio-socket-perl)
  • Perl Module: Date::Time (apt-get install libdatetime-perl)
  • Perl Module: Time::HiRes (In Debian/Ubuntu/Raspbian part of default per installation)
  • FHEM Module: 99_SUNRISE_EL.pm
  • FHEM Module: Blocking.pm

Define

define <name> SMAInverter <pin> <hostname/ip>

  • pin: User-Password of the SMA Inverter. Default is 0000. Can be changed by "Sunny Explorer" Windows Software
  • hostname/ip: Hostname or IP-Adress of the inverter (or it's speedwire piggyback module).
  • Port of the inverter is 9522 by default. Firewall has to allow connections on this port!

###Operation method The module sends commands to the inverter and checks if they are supported by the inverter. In case of a positive answer, the data is collected and displayed in the readings according to the detail-level.

If more than one inverter is installed, set attributes "target-susyid" and "target-serial" with an appropriate value.

The normal operation time of the inverter is supposed from sunrise to sunset. In that time period the inverter will be polled. The time of sunrise and sunset will be calculated by functions of FHEM module 99_SUNRISE_EL.pm which is loaded automatically by default. Therefore the global attribute "longitude" and "latitude" should be set to determine the position of the solar system

By the attribute "suppressSleep" the sleep mode between sunset and sunrise can be suppressed. Using attribute "offset" you may prefer the sunrise and defer the sunset virtually. So the working period of the inverter will be extended.

In operating mode "automatic" the inverter will be requested periodically corresponding the preset attribute "interval". The operating mode can be switched to "manual" to realize the retrieval manually (e.g. to synchronize the requst with a SMA energy meter by notify).

During inverter operating time, the average energy production of the last 5, 10 and 15 minutes will be calculated and displayed in the readings

"avg_power_lastminutes_05"

"avg_power_lastminutes_10"

and

``"avg_power_lastminutes_15".```

Note: To permit a precise calculation, you should also set the real request interval into the attribute "interval" although you would use the "manual" operation mode !

The retrieval of the inverter will be executed non-blocking. You can adjust the timeout value for this background process by attribute "timeout".

Get

get <name> data

The request of the inverter will be executed. Those possibility is especifically created for the "manual" operation mode (see attribute "mode").

Attributes

  • interval : Queryintreval in seconds
  • detail-level : "0" - Only Power and Energy / "1" - Including Voltage and Current / "2" - All values
  • disable : 1 = the module is disabled
  • mode : automatic = the inverter will be polled by preset interval, manual = query only by command "get <name> data"
  • offset : time in seconds to prefer the sunrise respectively defer the sunset virtualy (0 ... 7200). You will be able to extend the working
                              period of the module. </li>
    
  • SBFSpotComp : 1 = the readings are created like SBFSpot-style
  • suppressSleep : the sleep mode (after sunset, before sunrise) is deactivated and the inverter will be polled continuously.
  • showproctime : shows processing time in background and wasted time to retrieve inverter data
  • target-susyid : In case of a Multigate the target SUSyID can be defined. If more than one inverter is installed you have to
                              set the inverter-SUSyID to assign the inverter to the device definition.
    
                              Default is 0xFFFF, means any SUSyID</li>
    
  • target-serial : In case of a Multigate the target Serialnumber can be defined. If more than one inverter is installed you have to
                              set the inverter-Serialnumber to assign the inverter to the device definition.
    
    						  Default is 0xFFFFFFFF, means any Serialnumber</li>
    
  • timeout : setup timeout of inverter data request (default 60s)

###Readings

  • BAT_CYCLES / bat_cycles : Battery recharge cycles
  • BAT_IDC / bat_idc : Battery Current
  • BAT_TEMP / bat_temp : Battery temperature
  • BAT_UDC / bat_udc : Battery Voltage
  • ChargeStatus / chargestatus : Battery Charge status
  • CLASS / device_class : Inverter Class
  • PACMAX1 / pac_max_phase_1 : Nominal power in Ok Mode
  • PACMAX1_2 / pac_max_phase_1_2 : Maximum active power device (Some inverters like SB3300/SB1200)
  • PACMAX2 / pac_max_phase_2 : Nominal power in Warning Mode
  • PACMAX3 / pac_max_phase_3 : Nominal power in Fault Mode
  • Serialnumber / serial_number : Inverter Serialnumber
  • SPOT_ETODAY / etoday : Today yield
  • SPOT_ETOTAL / etotal : Total yield
  • SPOT_FEEDTM / feed-in_time : Feed-in time
  • SPOT_FREQ / grid_freq. : Grid Frequency
  • SPOT_IAC1 / phase_1_iac : Grid current phase L1
  • SPOT_IAC2 / phase_2_iac : Grid current phase L2
  • SPOT_IAC3 / phase_3_iac : Grid current phase L3
  • SPOT_IDC1 / string_1_idc : DC current input
  • SPOT_IDC2 / string_2_idc : DC current input
  • SPOT_OPERTM / operation_time : Operation Time
  • SPOT_PAC1 / phase_1_pac : Power L1
  • SPOT_PAC2 / phase_2_pac : Power L2
  • SPOT_PAC3 / phase_3_pac : Power L3
  • SPOT_PACTOT / total_pac : Total Power
  • SPOT_PDC1 / string_1_pdc : DC power input 1
  • SPOT_PDC2 / string_2_pdc : DC power input 2
  • SPOT_UAC1 / phase_1_uac : Grid voltage phase L1
  • SPOT_UAC2 / phase_2_uac : Grid voltage phase L2
  • SPOT_UAC3 / phase_3_uac : Grid voltage phase L3
  • SPOT_UDC1 / string_1_udc : DC voltage input
  • SPOT_UDC2 / string_2_udc : DC voltage input
  • SUSyID / susyid : Inverter SUSyID
  • INV_TEMP / device_temperature : Inverter temperature
  • INV_TYPE / device_type : Inverter Type
  • POWER_IN / power_in : Battery Charging power
  • POWER_OUT / power_out : Battery Discharging power
  • INV_GRIDRELAY / gridrelay_status : Grid Relay/Contactor Status
  • INV_STATUS / device_status : Inverter Status
  • opertime_start : Begin of iverter operating time corresponding the calculated time of sunrise with consideration of the
                                               attribute "offset" (if set) </li>
    
  • opertime_stop : End of iverter operating time corresponding the calculated time of sunrise with consideration of the
                                               attribute "offset" (if set) </li>
    
  • modulstate : shows the current module state "normal" or "sleep" if the inverter won't be requested at the time.
  • avg_power_lastminutes_05 : average power of the last 5 minutes.
  • avg_power_lastminutes_10 : average power of the last 10 minutes.
  • avg_power_lastminutes_15 : average power of the last 15 minutes.
  • inverter_processing_time : wasted time to retrieve the inverter data
  • background_processing_time : total wasted time by background process (BlockingCall)



Credits

FHEM-SMASTP

The module 77_SMASTP is deprecated.

It will be removed from the official FHEM soon.

Don't use it anymore!

Please use 76_SMAInverter.pm instead.

You'll find 76_SMAInverter.pm in the official FHEM SVN as well.

Support

Forum

SMA-EM

A forum for users of the SMA-EM module can be found at: https://forum.fhem.de/index.php/topic,51569.0.html

SMAInverter

A forum for users of the SMA-Inverter module can be found at: https://forum.fhem.de/index.php/topic,56080.0.html

SMA-STP

A forum for users of the SMA-STP module can be found at: https://forum.fhem.de/index.php/topic,42688.0.html

Issues

Please submit issues to github: https://github.com/kettenbach-it/FHEM-SMA-Speedwire/issues

Patches

In case you fix something, please submit a patch to https://github.com/kettenbach-it/FHEM-SMA-Speedwire/issues

Copyright

Volker Kettenbach, volker (at) kettenbach (minus) it (dot) de

Releases

No releases published

Packages

No packages published

Contributors 3

  •  
  •  
  •