7 changes: 6 additions & 1 deletion docs/currentchanges.txt
Original file line number Diff line number Diff line change
Expand Up @@ -106,4 +106,9 @@ V3.9.3
Minor release to allow install to work with the new Python version Adafruit install script.

V3.10
Significant release to add capability of using long presses and gestures on the touchscreen. HA light domain nodes (dimmers) and ISY nodes of type 1 (dimmers) now have the added feature that holding a long press on their screen buttons will bring up a brightness slider. Moving your finger along the axis of the slider will adjust brightness for the light. Note that due to differences in how Insteon/ISY and HA/Zwave handle dimming the physical responsiveness of HA nodes may look quicker at the light itself. This is due to rate limiting of the Insteon network traffic. Tapping OK will return to the parent screen with the new brightness while tapping Cancel will return but return the brightness to what it was. This feature also works for ISY Scenes via the console's scene proxy support so that the common idiom for implementing 3-way lights via a set of switches in a scene is supported as one would expect. Note that on capacitive touch screens this works very well and very responsively. Resistive touch screens generate a huge amount of "noise" in the form of non-existant touch/release events while holding down and other similar random things. The code has a lot of "dejittering" for all of this with the result that the resistive screens may seem a bit more sluggish in their response to finger movement, but in my experience still quite acceptable. The slider displays by default in the "long" direction of the screen but can be overriden, see the useage notes. In addition to these changes, there is now an alternate way to bring up the maintenance screen via a single diagonal gesture from the upper left to the lower right of the screen. (Note: if the screen is dim you do first need to awaken it with any touch.) Note that this has required a significant revamp to the touchscreen handling code so if you do see any apparent weirdness please report it. Also, given that the console can now see length of touch and movement, any suggestions for other uses of that capability are welcome. Finally, in the event that you do see strange problems with touch, you can for now revert to the previous touch driver system by creating an empty file in /home/pi names .forceoldtouch.
Significant release to add capability of using long presses and gestures on the touchscreen. HA light domain nodes (dimmers) and ISY nodes of type 1 (dimmers) now have the added feature that holding a long press on their screen buttons will bring up a brightness slider. Moving your finger along the axis of the slider will adjust brightness for the light. Note that due to differences in how Insteon/ISY and HA/Zwave handle dimming the physical responsiveness of HA nodes may look quicker at the light itself. This is due to rate limiting of the Insteon network traffic. Tapping OK will return to the parent screen with the new brightness while tapping Cancel will return but return the brightness to what it was. This feature also works for ISY Scenes via the console's scene proxy support so that the common idiom for implementing 3-way lights via a set of switches in a scene is supported as one would expect. Note that on capacitive touch screens this works very well and very responsively. Resistive touch screens generate a huge amount of "noise" in the form of non-existant touch/release events while holding down and other similar random things. The code has a lot of "dejittering" for all of this with the result that the resistive screens may seem a bit more sluggish in their response to finger movement, but in my experience still quite acceptable. The slider displays by default in the "long" direction of the screen but can be overriden, see the useage notes. In addition to these changes, there is now an alternate way to bring up the maintenance screen via a single diagonal gesture from the upper left to the lower right of the screen. (Note: if the screen is dim you do first need to awaken it with any touch.) Note that this has required a significant revamp to the touchscreen handling code so if you do see any apparent weirdness please report it. Also, given that the console can now see length of touch and movement, any suggestions for other uses of that capability are welcome. Finally, in the event that you do see strange problems with touch, you can for now revert to the previous touch driver system by creating an empty file in /home/pi names .forceoldtouch.

V3.10.1
Minor release to allow correct handling of HA hubs that use customized port instead of 8123. Also adds rate limiting of control traffic for HA dimming similar to that for ISY dimming. Adds support for multiple parameters for HA runprog key calls. Also includes various minor bug fixes and internal performance improvements.

setvar/getvar as cmds vs as special
41 changes: 34 additions & 7 deletions docs/useagenotes.md
Original file line number Diff line number Diff line change
Expand Up @@ -442,14 +442,35 @@ If you set a non empty title for a screen that doesn't otherwise have one, the r
of the screen (e.g., horizontally for the 7 inch screen in landscape mode and vertically for the smaller screen in
portrait mode). This can be overriden by explicitly specifying a SlideOrientation parameter where 0 is default
direction, 1 is force horizontal, and 2 is force vertical).
* RUNPROG: linked to a program to run. It issues a RunThen on the designated program for ISY hubs. It issues a
automation.trigger for the automation for HA hubs.
* (Deprecated-use RUNPROG with modifiers) ONBLINKRUNTHEN: linked to a program. Will blink to provide user feedback and will issue RunThen on program
* ON: will always send an "on" command to the linked device. This is useful for things like garage doors that use on toggles.
* RUNPROG: linked to a program to run. The program to run is specified by a **ProgramName** parameter. It issues a
RunThen on the designated program for ISY hubs. It issues a automation.trigger or script.<scriptname> for the
automation for HA hubs. A **Parameter** parameter may be supplied to provide parameter(s) to an HA script. (ISY
programs do not accept parameters.) The Parameter may be a single string in which case the json {'Parameter':
string} will be passed to HA. It may also be a comma delimited set of strings of the form A:vala,B:valb in which
case the json {'A':vala,'B':valb} will be passed.
* (Deprecated-use RUNPROG with modifiers) ONBLINKRUNTHEN: linked to a program. Will blink to provide user feedback
and will issue RunThen on program
* ON: will always send an "on" command to the linked device. This is useful for things like garage doors that use on
toggles.
* OFF: will always send an "off" command to the linked device.
* GOTO: Change to a specific screen. Takes a parameter ScreenName=<name of screen to go to>. Going to another screen creates a stack of screens. On the new screen the Nav keys will be "Home" and "Back". Back returns to the calling screen. Home returns to the top screen of the stack unless that is the screen Back would go to in which case Home goes to the global console home screen.
* GOTO: Change to a specific screen. Takes a parameter ScreenName=<name of screen to go to>. Going to another screen
creates a stack of screens. On the new screen the Nav keys will be "Home" and "Back". Back returns to the calling
screen. Home returns to the top screen of the stack unless that is the screen Back would go to in which case Home
goes to the global console home screen.
* SETVAR: set the value of an ISY variable
* VARKEY: this type can be used passively to construct status displays or also allow stepping through a predefined set of variable values. Its **Var** parameter specifies a store item to operate on. It has an **Appearance** parameter that specifies the display appearance of the key for various values of the store item. This parameter has the form of a list of comma delimited descriptor items. Each descriptor item is of the form "range color label" (without the quotes). Range is either a single integer that specifies a store item value or a pair n:m which defines a range within which the store item falls for this descriptor to be used. Color is the color of the key for this value. Label is the label the key should have for this value using semicolons to separate lines within the label and a $ to be substituted for the store item value if desired. If the label is left out of the descriptor item the normal key label is used (either the key name or an explicit label parameter). if the store value doesn't match any of the ranges the normal key label is used. A **ValueSeq** parameter optionally specifies values that should be cyclically assigned to the store item if the key is pressed. If the current value of the store item is not in the ValueSeq then a press sets the value to the first item in the sequence. Leaving it out makes the key passive. As an example should help clarify:
* VARKEY: this type can be used passively to construct status displays or also allow stepping through a predefined
set of variable values. Its **Var** parameter specifies a store item to operate on. It has an **Appearance**
parameter that specifies the display appearance of the key for various values of the store item. This parameter
has the form of a list of comma delimited descriptor items. Each descriptor item is of the form "range color
label" (without the quotes). Range is either a single integer that specifies a store item value or a pair n:m
which defines a range within which the store item falls for this descriptor to be used. Color is the color of the
key for this value. Label is the label the key should have for this value using semicolons to separate lines
within the label and a $ to be substituted for the store item value if desired. If the label is left out of the
descriptor item the normal key label is used (either the key name or an explicit label parameter). if the store
value doesn't match any of the ranges the normal key label is used. A **ValueSeq** parameter optionally specifies
values that should be cyclically assigned to the store item if the key is pressed. If the current value of the
store item is not in the ValueSeq then a press sets the value to the first item in the sequence. Leaving it out
makes the key passive. As an example should help clarify:
```
[[TestKey]]
type = VARKEY
Expand All @@ -459,7 +480,13 @@ If you set a non empty title for a screen that doesn't otherwise have one, the r
KeyCharColorOn = royalblue
Appearance = 0 green 'All good',1:2 yellow 'Probably; good; $',3:99 99 red 'Not so hot $'
```
This describes a key that will be green and say "All good" if the variable is 0; be yellow and say "Probably good" and show the value on 3 lines if the value is 1 or 2; and be red and say "Not so hot" and the value on a single line for values of 3 to 99. For any other values the key will display "Error in Value" and the value. Sequential presses of the key when the value is 0 will set the variable to 1, then 3, then 6, then 0. If something else has set the variable to, e.g.,4, then pressing it will make the variable 0.
This describes a key that will be green and say "All good" if the variable is 0; be yellow and say "Probably good"
and show the value on 3 lines if the value is 1 or 2; and be red and say "Not so hot" and the value on a single
line for values of 3 to 99. For any other values the key will display "Error in Value" and the value. Sequential
presses of the key when the value is 0 will set the variable to 1, then 3, then 6, then 0. If something else has
set the variable to, e.g.,4, then pressing it will make the variable 0. A **ProgramName** parameter may be
optionally specified that will cause that script/program to be run in the hub (exactly as a RUNPROG key). In this
case a **Parameter** parameter may also be supplied.
* Note the key types PROC, REMOTEPROC, and REMOTECPLXPROC are reserved for internal use by the console.
Expand Down

0 comments on commit 757235a

Please sign in to comment.