Skip to content

mtconnect/cppagent

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

MTConnect C++ Agent Version 2.3

Build MTConnect C++ Agent

The C++ Agent provides the a complete implementation of the HTTP server required by the MTConnect standard. The agent provides the protocol and data collection framework that will work as a standalone server. Once built, you only need to specify the XML description of the devices and the location of the adapter.

NOTE: This version cannot currently be built on Windows XP since there is currently no support for the XP toolchain and C++ 17.

Pre-built binary releases for Windows are available from Releases for those who do not want to build the agent themselves. For *NIX users, you will need libxml2, cppunit, and cmake as well as build essentials.

Version 2.3.0 Support for all Version 2.3 standard changes and JSON ingress to MQTT adapter.

Version 2.2.0 Support for all Version 2.2 standard changes and dynamic configuration from adapters. Upgrade to conan 2.

Version 2.1.0 Added MQTT Sink, Agent Restart and new JSON format (version 2)

Version 2.0.0 Rearchitecture of the agent with TLS, MQTT Adapter, Ruby Interpreter, Agent Adaptr, and much more

Version 1.7.0 added kinematics, solid models, and new specifications types.

Version 1.6.0 added coordinate systems, specifications, and tabular data.

Version 1.5.0 added Data Set capabilities and has been updated to use C++ 14.

Version 1.4.0 added time period filter constraint, compositions, initial values, and reset triggers.

Version 1.3.0 added the filter constraints, references, cutting tool archetypes, and formatting styles.

Version 1.2.0 added the capability to support assets.

Version 1.1.0.8 add the ability to run the C++ Agent as a Windows service and support for a configuration file instead of command line arguments. The agent can accept input from a socket in a pipe (|) delimited stream according to the descriptions given in the adapter guide.

The current win32 binary is built statically and requires no additional dlls to run. This allows for a single exe distributable.

Usage

agent [help|install|debug|run] [configuration_file]
   help           Prints this message
   install        Installs the service
   remove         Remove the service
   debug          Runs the agent on the command line with verbose logging -
                  sets logging_level to debug
   run            Runs the agent on the command line
   config_file    The configuration file to load
                  Default: agent.cfg in current directory

When the agent is started without any arguments it is assumed it will be running as a service and will begin the service initialization sequence. The full path to the configuration file is stored in the registry in the following location:

\\HKEY_LOCAL_MACHINE\SOFTWARE\MTConnect\MTConnect Agent\ConfigurationFile

Directories

  • agent/ - This contains the application source files and CMake file.

  • assets/ - Some example Cutting Tool asset files.

  • lib/ - Third party library source. Contains source for cppunit, dlib, and libxml++.

  • samples/ - Sample XML configuration files mainly used for tests.

  • simulator/ - Ruby scripts to execute an adapter simulator, both command-line and log-replay.

  • test/ - Various unit tests.

  • tools/ - Ruby scripts to dump the agent and the adapter in SHDR format. Includes a sequence test script.

  • unix/ - Unix init.d script

  • win32/ - Libraries required only for the win32 build and the win32 solution.

Windows Binary Release

The windows binary releases come with a prebuilt exe that is statically linked with the Microsoft Runtime libraries. Aside from the standard system libraries, the agent only requires winsock libraries. The agent has been test with version of Windows 2000 and later.

  • bin/ - Win32 binary (no dependencies required).

Building

Platform specific instructions are at the end of the README.

Configuration

The configuration file is using the standard Boost C++ file format. The configuration file format is flexible and allows for both many adapters to be served from one agent and an adapter to feed multiple agents. The format is:

Key = Value

The key can only occur once within a section and the value can be any sequence of characters followed by a <CR>. There no significance to the order of the keys, so the file can be specified in free form. We will go over some configurations from a minimal configuration to more complex multi-adapter configurations.

Serving Static Content

Using a Files Configuration section, individual files or directories can be inserted into the request file space from the agent. To do this, we use the Files top level configuration declaration as follows:

Files {
    schemas {
        Path = ../schemas
        Location = /schemas/
    }
    styles {
        Path = ../styles
        Location = /styles/
    }
}

Each set of files must be declared using a named file description, like schema or styles and the local Path and the Location the files will be mapped to in the HTTP server namespace. For example:

http://example.com:5000/schemas/MTConnectStreams_2.0.xsd will map to ../schemas/MTConnectStreams_2.0.xsd

All files will be mapped and the directory names do not need to be the same. These files can be either served directly or can be used to extend the schema or add XSLT stylesheets for formatting the XML in browsers.

Specifying the Extended Schemas

To specify the new schema for the documents, use the following declaration:

StreamsNamespaces {
  e {
    Urn = urn:example.com:ExampleStreams:2.0
    Location = /schemas/ExampleStreams_2.0.xsd
  }
}

This will use the ExampleStreams_2.0.xsd schema in the document. The e is the alias that will be used to reference the extended schema. The Location is the location of the xsd file relative in the agent namespace. The Location must be mapped in the Files section.

An optional Path can be added to the ...Namespaces declaration instead of declaring the Files section. The Files makes it easier to include multiple files from a directory and will automatically include all the default MTConnect schema files for the correct version. (See SchemaVersion option below)

You can do this for any one of the other documents:

StreamsNamespaces
DevicesNamespaces
AssetsNamespaces
ErrorNamespaces

Specifying the XML Document Style

The same can be done with style sheets, but only the Location is required.

StreamsStyle {
  Location = /styles/Streams.xsl
}

An optional Path can also be used to reference the xsl file directly. This will not include other files in the path like css or included xsl transforms. It is advised to use the Files declaration.

The following can also be declared:

DevicesStyle
StreamsStyle
AssetsStyle
ErrorStyle

Example 1:

Here’s an example configuration file. The # character can be used to comment sections of the file. Everything on the line after the # is ignored. We will start with an extremely simple configuration file.

# A very simple file...
Devices = VMC-3Axis.xml

This is a one line configuration that specifies the XML file to load for the devices. Since all the values are defaulted, an empty configuration file can be specified. This configuration file will load the VMC-3Axis.xml file and try to connect to an adapter located on the localhost at port 7878. VMC-3Axis.xml must only contain the definition for one device; if more devices exist, an error will be raised and the process will exit.

Example 2:

Most configuration files will specify at least one adapter. The adapters are contained within a block. The Boost configuration file format allows for nested configurations and block associations. There are a number of configurations that can be given for each adapter. Multiple adapters can be specified for one device as well.

Devices = VMC-3Axis.xml

Adapters
{
    VMC-3Axis
    {
        Host = 192.168.10.22
        Port = 7878 # *Default* value...
    }
}

This example loads the devices file as before, but specifies the list of adapters. The device is taken from the name VMC-3Axis that starts the nested block and connects to the adapter on 192.168.10.22 and port 7878. Another way of specifying the equivalent configuration is:

Devices = VMC-3Axis.xml

Adapters
{
    Adapter_1
    {
        Device = VMC-3Axis
        Host = 192.168.10.22
        Port = 7878 # *Default* value...
    }
}

Line 7 specifies the Device name associated with this adapter explicitly. We will show how this is used in the next example.

Example 3:

Multiple adapters can supply data to the same device. This is done by creating multiple adapter entries and specifying the same Device for each.

Devices = VMC-3Axis.xml

Adapters
{
    Adapter_1
    {
        Device = VMC-3Axis
        Host = 192.168.10.22
        Port = 7878 # *Default* value...
    }

    # Energy sensor
    Adapter_2
    {
        Device = VMC-3Axis
        Host = 192.168.10.2
        Port = 7878 # *Default* value...
    }
}

Both Adapter_1 and Adapter_2 will feed the VMC-3Axis device with different data items. The Adapter_1 name is arbitrary and could just as well be named EnergySensor if desired as illustrated below.

Devices = VMC-3Axis.xml

Adapters
{
    Controller
    {
        Device = VMC-3Axis
        Host = 192.168.10.22
        Port = 7878 # *Default* value...
    }

    EnergySensor
    {
        Device = VMC-3Axis
        Host = 192.168.10.2
        Port = 7878 # *Default* value...
    }
}

Example 4:

In this example we change the port to 80 which is the default http port. This also allows HTTP PUT from the local machine and 10.211.55.2.

Devices = MyDevices.xml
Port = 80
AllowPutFrom = localhost, 10.211.55.2

Adapters
{
    ...

For browsers you will no longer need to specify the port to connect to.

Example 5:

If multiple devices are specified in the XML file, there must be an adapter feeding each device.

Devices = MyDevices.xml

Adapters
{
    VMC-3Axis
    {
        Host = 192.168.10.22
    }

    HMC-5Axis
    {
        Host = 192.168.10.24
    }
}

This will associate the adapters for these two machines to the VMC and HMC devices in MyDevices.xml file. The ports are defaulted to 7878, so we are not required to specify them.

Example 6:

In this example we demonstrate how to change the service name of the agent. This allows a single machine to run multiple agents and/or customize the name of the service. Multiple configuration files can be created for each service, each with a different ServiceName. The configuration file must be referenced as follows:

C:> agent install myagent.cfg

If myagent.cfg contains the following statements:

Devices = MyDevices.xml
ServiceName = MTC Agent 1

Adapters
{
    ...

The service will now be displayed as "MTC Agent 1" as opposed to "MTConnect Agent" and it will automatically load the contents of myagent.cfg with it starts. You can now use the following command to start this from a command prompt:

C:> net start "MTC Agent 1"

To remove the service, do the following:

C:> agent remove myagent.cfg

Example 7:

Logging configuration is specified using the logger_config block. You can change the logging_level to specify the verbosity of the logging as well as the destination of the logging output.

logger_config
{
    logging_level = debug
    output = file debug.log
}

This will log everything from debug to fatal to the file debug.log. For only fatal errors you can specify the following:

logger_config
{
    logging_level = fatal
}

The default file is agent.log in the same directory as the agent.exe file resides. The default logging level is info. To have the agent log to the command window:

logger_config
{
    logging_level = debug
    output = cout
}

This will log debug level messages to the current console window. When the agent is run with debug, it sets the logging configuration to debug and outputs to the standard output as specified above.

Example: 8

The MTConnect C++ Agent supports extensions by allowing you to specify your own XSD schema files. These files must include the MTConnect schema and the top level node is required to be MTConnect. The "x" in this case is the namespace. You MUST NOT use the namespace "m" since it is reserved for MTConnect. See example 9 for an example of changing the MTConnect schema file location.

There are four namespaces in MTConnect: Devices, Streams, Assets, and Error. In this example we will replace the Streams and Devices namespace with our own namespace so we can have validatable XML documents.

StreamsNamespaces {
  x {
    Urn = urn:example.com:ExampleStreams:1.2
    Location = /schemas/ExampleStreams_1.2.xsd
    Path = ./ExampleStreams_1.2.xsd
  }
}

DevicesNamespaces {
  x {
    Urn = urn:example.com:ExampleDevices:1.2
    Location = /schemas/ExampleDevices_1.2.xsd
    Path = ./ExampleDevices_1.2.xsd
  }
}

For each schema file we have three options we need to specify. The Urn is the urn in the schema file that will be used in the header. The Location is the path specified in the URL when requesting the schema file from the HTTP client and the Path is the path on the local file system.

Example: 9

If you only want to change the schema location of the MTConnect schema files and serve them from your local agent and not from the default internet location, you can use the namespace "m" and give the new schema file location. This MUST be the MTConnect schema files and the urn will always be the MTConnect urn for the "m" namespace -- you cannot change it.

StreamsNamespaces {
  m {
    Location = /schemas/MTConnectStreams_2.0.xsd
    Path = ./MTConnectStreams_2.0.xsd
  }
}

DevicesNamespaces {
  m {
    Location = /schemas/MTConnectDevices_2.0.xsd
    Path = ./MTConnectDevices_2.0.xsd
  }
}

The MTConnect agent will now serve the standard MTConnect schema files from the local directory using the schema path /schemas/MTConnectDevices_2.0.xsd.

Example: 10

We can also serve files from the MTConnect Agent as well. In this example we can assume we don't have access to the public internet and we would still like to provide the MTConnect streams and devices files but have the MTConnect Agent serve them up locally.

DevicesNamespaces {
  x {
    Urn = urn:example.com:ExampleDevices:2.0
    Location = /schemas/ExampleDevices_2.0.xsd
    Path = ./ExampleDevices_2.0.xsd
  }

Files {
  stream { 
    Location = /schemas/MTConnectStreams_2.0.xsd
    Path = ./MTConnectStreams_2.0.xsd
  }
  device { 
    Location = /schemas/MTConnectDevices_2.0.xsd
    Path = ./MTConnectDevices_2.0.xsd
  }
}

Or use the short form for all files:

    Files {
      schemas { 
        Location = /schemas/MTConnectStreams_2.0.xsd
        Path = ./MTConnectStreams_2.0.xsd
      }
    }

If you have specified in your xs:include schemaLocation inside the ExampleDevices_2.0.xsd file the location "/schemas/MTConnectStreams_2.0.xsd", this will allow it to be served properly. This can also be done using the Devices namespace:

DevicesNamespaces {
  m {
    Location = /schemas/MTConnectDevices_2.0.xsd
    Path = ./MTConnectDevices_2.0.xsd
  }
}

The MTConnect agent will allow you to serve any other files you wish as well. You can specify a new static file you would like to deliver:

Files {
  myfile { 
    Location = /files/xxx.txt
    Path = ./files/xxx.txt
  }

The agent will not serve all files from a directory and will not provide an index function as this is insecure and not the intended function of the agent.

Ruby

If the "-o with_ruby=True" build is selected, then use to following configuration:

Ruby {
  module = path/to/module.rb
}

The module specified at the path given will be loaded. There are examples in the test/Resources/ruby directory in github: Ruby Tests.

The current functionality is limited to the pipeline transformations from the adapters. Future changes will include adding sources and sinks.

The following is a complete example for fixing the Execution of a machine:

class AlertTransform < MTConnect::RubyTransform
  def initialize(name, filter)
    @cache = Hash.new
    super(name, filter)
  end

  @@count = 0
  def transform(obs)
    @@count += 1
    if @@count % 10000 == 0
      puts "---------------------------"
      puts ">  #{ObjectSpace.count_objects}"
      puts "---------------------------"
    end
    
    dataItemId = obs.properties[:dataItemId]
    if dataItemId == 'servotemp1' or dataItemId == 'Xfrt' or dataItemId == 'Xload'
      @cache[dataItemId] = obs.value
      device = MTConnect.agent.default_device
      
      di = device.data_item('xaxisstate')
      if @cache['servotemp1'].to_f > 10.0 or @cache['Xfrt'].to_f > 10.0 or @cache['Xload'].to_f > 10
        newobs = MTConnect::Observation.new(di, "ERROR")
      else
        newobs = MTConnect::Observation.new(di, "OK")
      end
      forward(newobs)
    end
    forward(obs)
  end
end
    
MTConnect.agent.sources.each do |s|
  pipe = s.pipeline
  puts "Splicing the pipeline"
  trans = AlertTransform.new('AlertTransform', :Sample)
  puts trans
  pipe.splice_before('DeliverObservation', trans)
end

Configuration Parameters

Top level configuration items

  • AgentDeviceUUID - Set the UUID of the agent device

    Default: UUID derived from the IP address and port of the agent

  • BufferSize - The 2^X number of slots available in the circular buffer for samples, events, and conditions.

    Default: 17 -> 2^17 = 131,072 slots.

  • CheckpointFrequency - The frequency checkpoints are created in the stream. This is used for current with the at argument. This is an advanced configuration item and should not be changed unless you understand the internal workings of the agent.

    Default: 1000

  • CreateUniqueIds: Changes all the ids in each element to a UUID that will be unique across devices. This is used for merging devices from multiple sources.

    Default: false

  • Devices - The XML file to load that specifies the devices and is supplied as the result of a probe request. If the key is not found the defaults are tried.

    Defaults: probe.xml or Devices.xml

  • DisableAgentDevice - When the schema version is >= 1.7, disable the creation of the Agent device.

    Default: false

  • JsonVersion - JSON Printer format. Old format: 1, new format: 2

    Default: 2

  • LogStreams - Debugging flag to log the streamed data to a file. Logs to a file named: Stream_ + timestamp + .log in the current working directory. This is only for the Rest Sink.

    Default: false

  • MaxAssets - The maximum number of assets the agent can hold in its buffer. The number is the actual count, not an exponent.

    Default: 1024

  • MaxCachedFileSize - The maximum size of a raw file to cache in memory.

    Default: 20 kb

  • MinCompressFileSize - The file size where we begin compressing raw files sent to the client.

    Default: 100 kb

  • MinimumConfigReloadAge - The minimum age of a config file before an agent reload is triggered (seconds).

    Default: 15 seconds

  • MonitorConfigFiles - Monitor agent.cfg and Devices.xml files and restart agent if they change.

    Default: false

  • MonitorInterval - The interval between checks if the agent.cfg or Device.xml files have changed.

    Default: 10 seconds

  • Pretty - Pretty print the output with indententation

    Default: false

  • PidFile - UNIX only. The full path of the file that contains the process id of the daemon. This is not supported in Windows.

    Default: agent.pid

  • SchemaVersion - Change the schema version to a different version number.

    Default: 2.0

  • Sender - The value for the sender header attribute.

    Default: Local machine name

  • ServiceName - Changes the service name when installing or removing the service. This allows multiple agents to run as services on the same machine.

    Default: MTConnect Agent

  • SuppressIPAddress - Suppress the Adapter IP Address and port when creating the Agent Device ids and names. This applies to all adapters.

    Default: false

  • VersionDeviceXml - Create a new versioned file every time the Device.xml file changes from an external source.

    Default: false

  • WorkerThreads - The number of operating system threads dedicated to the Agent

    Default: 1

Adapter General Configuration

These can be overridden on a per-adapter basis

  • Protocol –Specify protocol. Options: [shdr|mqtt]

    Default: shdr

  • ConversionRequired - Global default for data item units conversion in the agent. Assumes the adapter has already done unit conversion.

    Default: true

  • EnableSourceDeviceModels - Allow adapters and data sources to supply Device configuration

    Default: false

  • Heartbeat – Overrides the heartbeat interval sent back from the adapter in the * PONG <hb>. The heartbeat will always be this value in milliseconds.

    Default: None

  • IgnoreTimestamps - Overwrite timestamps with the agent time. This will correct clock drift but will not give as accurate relative time since it will not take into consideration network latencies. This can be overridden on a per adapter basis.

    Default: false

  • LegacyTimeout - The default length of time an adapter can be silent before it is disconnected. This is only for legacy adapters that do not support heartbeats.

    Default: 600

  • PreserveUUID - Do not overwrite the UUID with the UUID from the adapter, preserve the UUID in the Devices.xml file. This can be overridden on a per adapter basis.

    Default: true

  • ReconnectInterval - The amount of time between adapter reconnection attempts. This is useful for implementation of high performance adapters where availability needs to be tracked in near-real-time. Time is specified in milliseconds (ms).

    Default: 10000

  • ShdrVersion - Specifies the SHDR protocol version used by the adapter. When greater than one (1), allows multiple complex observations, like Condition and Message on the same line. If it equials one (1), then any observation requiring more than a key/value pair need to be on separate lines. This is the default for all adapters.

    Default: 1

  • UpcaseDataItemValue - Always converts the value of the data items to upper case.

    Default: true

REST Service Configuration

  • AllowPut - Allow HTTP PUT or POST of data item values or assets.

    Default: false

  • AllowPutFrom - Allow HTTP PUT or POST from a specific host or list of hosts. Lists are comma (,) separated and the host names will be validated by translating them into IP addresses.

    Default: none

  • HttpHeaders - Additional headers to add to the HTTP Response for CORS Security

    Example:

     HttpHeaders {
     	Access-Control-Allow-Origin = *
     	Access-Control-Allow-Methods = GET
     	Access-Control-Allow-Headers = Content-Type
     }
    
  • Port - The port number the agent binds to for requests.

    Default: 5000

  • ServerIp - The server IP Address to bind to. Can be used to select the interface in IPV4 or IPV6.

    Default: 0.0.0.0

Configuration Pameters for TLS (https) Support

The following parameters must be present to enable https requests. If there is no password on the certificate, TlsCertificatePassword may be omitted.

  • TlsCertificateChain - The name of the file containing the certificate chain created from signing authority

    Default: NULL

  • TlsCertificatePassword - The password used when creating the certificate. If none was supplied, do not use.

    Default: NULL

  • TlsClientCAs - For TlsVerifyClientCertificate, specifies a file that contains additional certificate authorities for verification

    Default: NULL

  • TlsDHKey - The name of the file containing the Diffie–Hellman key

    Default: NULL

  • TlsOnly - Only allow secure connections, http requests will be rejected

    Default: false

  • TlsPrivateKey - The name of the file containing the private key for the certificate

    Default: NULL

  • TlsVerifyClientCertificate - Request and verify the client certificate against root authorities

    Default: false

MQTT Configuration

  • MqttCaCert - CA Certificate for MQTT TLS connection to the MTT Broker

    Default: NULL

  • MqttHost - IP Address or name of the MQTT Broker

    Default: 127.0.0.1

  • MqttPort - Port number of MQTT Broker

    Default: 1883

  • MqttTls - TLS Certificate for secure connection to the MQTT Broker

    Default: false

  • MqttWs - Instructs MQTT to connect using web sockets

    Default: false

MQTT Sink

Enabled in agent.cfg by specifying:

Sinks {
  MqttService {
    # Configuration Options below...
  }
}
  • DeviceTopic - Prefix for the Device Model topic

    Default: MTConnect/Device/

  • ObservationTopic - Prefix for the Streams events, samples, and conditions

    Default: MTConnect/Observation/

  • AssetTopic - Prefix for the Assets

    Default: MTConnect/Asset/

MQTT Sink 2

Enabled in agent.cfg by specifying:

Sinks {
  Mqtt2Service {
    # Configuration Options...
  }
}
  • AssetTopic - Prefix for the Assets

    Default: MTConnect/Asset/[device]

  • CurrentTopic - Prefix for the Current

    Default: MTConnect/Current/[device]

  • ProbeTopic or DeviceTopic - Prefix for the Device Model topic

    Note: [device] will be replaced with the uuid of each device. Other patterns can be created, for example: MTConnect/[device]/Probe will group by device instead of operation. DeviceTopic will also work.

    Default: MTConnect/Probe/[device]

  • SampleTopic - Prefix for the Sample

    Default: MTConnect/Sample/[device]

  • MqttLastWillTopic - The topic used for the last will and testement for an agent

    Note: The value will be AVAILABLE when the Agent is publishing and connected and will publish UNAVAILABLE when the agent disconnects from the broker.

    Default: MTConnect/Probe/[device]/Availability"

  • MqttCurrentInterval - The frequency to publish currents. Acts like a keyframe in a video stream.

    Default: 10000ms

  • MqttSampleInterval - The frequency to publish samples. Works the same way as the interval in the rest call. Groups observations up and publishes with the minimum interval given. If nothing is availble, will wait until an observation arrives to publish.

    Default: 500ms

  • MqttSampleCount - The maxmimum number of observations to publish at one time.

    Default: 1000

  • MqttRetain - For the MQTT Sinks, sets the retain flag for publishing.

    Default: True

  • MqttQOS: - For the MQTT Sinks, sets the Quality of Service. Must be one of at_least_once, at_most_once, exactly_once.

    Default: at_least_once

  • MqttXPath: - The xpath filter to apply to all current and samples published to MQTT. If the XPath is invalid, it will fall back to publishing all data items.

    Default: All data items

Adapter Configuration Items

  • Adapters - Contains a list of device blocks. If there are no Adapters specified and the Devices file contains one device, the Agent defaults to an adapter located on the localhost at port 7878. Data passed from the Adapter is associated with the default device.

    Default: localhost 7878, associated with the default device

    • Device - The name of the device that corresponds to the name of the device in the Devices file. Each adapter can map to one device. Specifying a "*" will map to the default device.

      Default: The name of the block for this adapter or if that is not found the default device if only one device is specified in the devices file.

    • Host - The host the adapter is located on.

      Default: localhost

    • Port - The port to connect to the adapter.

      Default: 7878

    • Manufacturer - Replaces the manufacturer attribute in the device XML.

      Default: Current value in device XML.

    • Station - Replaces the Station attribute in the device XML.

      Default: Current value in device XML.

    • SerialNumber - Replaces the SerialNumber attribute in the device XML.

      Default: Current value in device XML.

    • UUID - Replaces the UUID attribute in the device XML.

      Default: Current value in device XML.

    • AutoAvailable - For devices that do not have the ability to provide available events, if yes, this sets the Availability to AVAILABLE upon connection.

      Default: no (new in 1.2, if AVAILABILITY is not provided for device it will be automatically added and this will default to yes)

    • AdditionalDevices - Comma separated list of additional devices connected to this adapter. This provides availability support when one adapter feeds multiple devices.

      Default: nothing

    • FilterDuplicates - If value is yes, filters all duplicate values for data items. This is to support adapters that are not doing proper duplicate filtering.

      Default: no

    • LegacyTimeout - length of time an adapter can be silent before it is disconnected. This is only for legacy adapters that do not support heartbeats. If heartbeats are present, this will be ignored.

      Default: 600

    • ReconnectInterval - The amount of time between adapter reconnection attempts. This is useful for implementation of high performance adapters where availability needs to be tracked in near-real-time. Time is specified in milliseconds (ms). Defaults to the top level ReconnectInterval.

      Default: 10000

    • IgnoreTimestamps - Overwrite timestamps with the agent time. This will correct clock drift but will not give as accurate relative time since it will not take into consideration network latencies. This can be overridden on a per adapter basis.

      Default: Top Level Setting

    • PreserveUUID - Do not overwrite the UUID with the UUID from the adapter, preserve the UUID in the Devices.xml file. This can be overridden on a per adapter basis.

        *Default*: false
      
    • RealTime - Boost the thread priority of this adapter so that events are handled faster.

      Default: false

    • RelativeTime - The timestamps will be given as relative offsets represented as a floating point number of milliseconds. The offset will be added to the arrival time of the first recorded event.

      Default: false

    • ConversionRequired - Adapter setting for data item units conversion in the agent. Assumes the adapter has already done unit conversion. Defaults to global.

      Default: Top Level Setting

    • UpcaseDataItemValue - Always converts the value of the data items to upper case.

      Default: Top Level Setting

    • ShdrVersion - Specifies the SHDR protocol version used by the adapter. When greater than one (1), allows multiple complex observations, like Condition and Message on the same line. If it equials one (1), then any observation requiring more than a key/value pair need to be on separate lines. Applies to only this adapter.

      Default: 1

    • SuppressIPAddress - Suppress the Adapter IP Address and port when creating the Agent Device ids and names.

      Default: false

    • AdapterIdentity - Adapter Identity name used to prefix dataitems within the Agent device ids and names.

      Default:

      • If SuppressIPAddress == false:
        AdapterIdentity = _ {IP}_{PORT}
        example:_localhost_7878

      • If SuppressIPAddress == true:
        AdapterIdentity = _ sha1digest({IP}_{PORT})
        example: __71020ed1ed

MQTT Adapter/Source

  • MqttHost - IP Address or name of the MQTT Broker

    Default: 127.0.0.1

  • MqttPort - Port number of MQTT Broker

    Default: 1883

  • topics - list of topics to subscribe to. Note : Only raw SHDR strings supported at this time

    Required

  • MqttClientId - Port number of MQTT Broker

    Default: Auto-generated

    Example mqtt adapter block:

     mydevice {
     		Protocol = mqtt
     		MqttHost = localhost
     		MqttPort = 1883
     		MqttClientId = myUniqueID
     		Topics = /ingest
     	}
  • AdapterIdentity - Adapter Identity name used to prefix dataitems within the Agent device ids and names.

    Default:

    • If SuppressIPAddress == false:
      AdapterIdentity = _ {IP}_{PORT}
      example:_localhost_7878

    • If SuppressIPAddress == true:
      AdapterIdentity = _ sha1digest({IP}_{PORT})
      example: __71020ed1ed

Agent Adapter Configuration

  • Url - The URL of the source agent. http: or https: are accepted for the protocol.

  • SourceDevice – The Device name or UUID for the source of the data

  • Count – the number of items request during a single sample

    Default: 1000

  • Polling Interval – The interval used for streaming or polling in milliseconds

    Default: 500ms

  • Reconnect Interval – The interval between reconnection attampts in milliseconds

    Default: 10000ms

  • Use Polling – Force the adapter to use polling instead of streaming. Only set to true if x-multipart-replace blocked.

    Default: false

  • Heartbeat – The heartbeat interval from the server

    Default: 10000ms

logger_config configuration items

  • logger_config - The logging configuration section.

    • logging_level - The logging level: trace, debug, info, warn, error, or fatal.

      Default: info

      Note: when running Agent with agent debug, logging_level will be set to debug.

    • output - The output file or stream. If using a file, specify as: "file <filename>". cout and cerr can be used to specify the standard output and standard error streams. Defaults to the same directory as the executable.

      Default: file adapter.log

    • max_size - The maximum log file size. Suffix can be K for kilobytes, M for megabytes, or G for gigabytes. No suffix will default to bytes (B). Case is ignored.

      Default: 10M

    • max_index - The maximum number of log files to keep.

      Default: 9

    • schedule - The scheduled time to start a new file. Can be DAILY, WEEKLY, or NEVER.

      Default: NEVER

Agent-Adapter Protocols

SHDR Version 2.0

The principle adapter data format is a simple plain text stream separated by the pipe character |. Every line except for commands starts with an optional timestamp in UTC. If the timestamp is not supplied the agent will supply a timestamp of its own taken at the arrival time of the data to the agent. The remainder of the line is a key followed by data – depending on the type of data item is being written to.

A simple set of events and samples will look something like this:

2009-06-15T00:00:00.000000|power|ON|execution|ACTIVE|line|412|Xact|-1.1761875153|Yact|1766618937

A line is a sequence of fields separated by |. The simplest requires one key/value pair. The agent will discard any lines where the data is malformed. The end must end with a LF (ASCII 10) or CR-LF (ASCII 15 followed by ASCII 10) (UNIX or Windows conventions respectively). The key will map to the data item using the following items: the id attribute, the name attribute, and the CDATA of the Source element. If the key does not match it will be rejected and the agent will log the first time it fails. Different data items categories and types require a different number of tokens. The following rules specify the requirements for the adapter tokens:

If the value itself contains a pipe character | the pipe must be escaped using a leading backslash \. In addition the entire value has to be wrapped in quotes:

    2009-06-15T00:00:00.000000|description|"Text with \| (pipe) character."

Conditions require six (6) fields as follows:

<timestamp>|<data_item_name>|<level>|<native_code>|<native_severity>|<qualifier>|<message>

Condition id and native code are set to the same value given as <native_code>

<timestamp>|<data_item_name>|<level>|<native_code>:<condition_id>|<native_severity>|<qualifier>|<message>

Condition id is set to condition_id and native code is set to native_code

<timestamp>|<data_item_name>|<level>|<condition_id>|<native_severity>|<qualifier>|<message>

Condition id is set to condition_id and native code is not set

For a complete description of these fields, see the standard. An example line will look like this:

2014-09-29T23:59:33.460470Z|htemp|WARNING|HTEMP-1-HIGH|HTEMP|1|HIGH|Oil Temperature High

The next special format is the Message. There is one additional field, native_code, which needs to be included:

2014-09-29T23:59:33.460470Z|message|CHG_INSRT|Change Inserts

Time series data also gets special treatment, the count and optional frequency are specified. In the following example we have 10 items at a frequency of 100hz:

2014-09-29T23:59:33.460470Z|current|10|100|1 2 3 4 5 6 7 8 9 10

The data item name can also be prefixed with the device name if this adapter is supplying data to multiple devices. The following is an example of a power meter for three devices named device1, device2, and device3:

2014-09-29T23:59:33.460470Z|device1:current|12|device2:current|11|device3:current|10

All data items follow the formatting requirements in the MTConnect standard for the vocabulary and coordinates like PathPosition.

A new feature introduced in version 1.4 is the ability to announce a reset has been triggered. If we have a part count named pcount that gets reset daily, the new protocol is as follows:

2014-09-29T23:59:33.460470Z|pcount|0:DAY

To specify the duration of the static, indicate it with an @ sign after the timestamp as follows:

2014-09-29T23:59:[email protected]|pcount|0:DAY

DATA_SET Representation

A new feature in version 1.5 is the DATA_SET representation which allows for key value pairs to be given. The protocol is similar to time series where each pair is space delimited. The agent automatically removes duplicate values from the stream and allows for addition, deletion and resetting of the values. The format is as follows:

2014-09-29T23:59:33.460470Z|vars|v1=10 v2=20 v3=30

This will create a set of three values. To remove a value

2014-09-29T23:59:33.460470Z|vars|v2 v3=

This will remove v2 and v3. If text after the equal = is empty or the = is not given, the value is deleted. To clear the set, specify a resetTriggered value such as MANUAL or DAY by preceeding it with a colon : at the beginning of the line.

2014-09-29T23:59:33.460470Z|vars|:MANUAL

This will remove all the values from the current set. The set can also be reset to a specific set of values:

2014-09-29T23:59:33.460470Z|vars|:MANUAL v5=1 v6=2

This will remove all the old values from the set and set the current set. Values will accumulate when addition pairs are given as in:

2014-09-29T23:59:33.460470Z|vars|v8=1 v9=2 v5=10

This will add values for v8 and v9 and update the value for v5 to 10. If the values are duplcated they will be removed from the stream unless a resetTriggered value is given.

2014-09-29T23:59:33.460470Z|vars|v8=1 v9=2 v5=0

Will be detected as a duplicate with respect to the previous values and will be removed. If a partial update is given and the other values are duplicates, then will be stripped:

2014-09-29T23:59:33.460470Z|vars|v8=1 v9=3 v5=10

Will be effectively the same as specifying:

2014-09-29T23:59:33.460470Z|vars|v9=2

And the streams will only have the one value when a sample is request is made at that point in the stream.

When the discrete flag is set to true in the data item, all change tracking is ignored and each set is treated as if it is new.

One can quote values using the following methods: "<text>", '<text>', and {<text>}. Spaces and other characters can be included in the text and the matching character can be escaped with a \ if it is required as follows: "hello \"there\"" will yield the value: hellow "there".

TABLE Representation

A TABLE representation is similar to the DATA_SET that has a key value pair as the value. Using the encoding mentioned above, the following representations are allowed for tables:

<timestamp>|wpo|G53.1={X=1.0 Y=2.0 Z=3.0 s='string with space'} G53.2={X=4.0 Y=5.0 Z=6.0} G53.3={X=7.0 Y=8.0 Z=9 U=10.0}

Using the quoting conventions explained in the previous section, the inner content can contain quoted text and exscaped values. The value is interpreted as a key/value pair in the same way as the DATA_SET. A table can be thought of as a data set of data sets.

All the reset rules of data set apply to tables and the values are treated as a unit.

Assets

Assets are associated with a device but do not have a data item they are mapping to. They therefore get the special data item name @ASSET@. Assets can be sent either on one line or multiple lines depending on the adapter requirements. The single line form is as follows:

2012-02-21T23:59:33.460470Z|@ASSET@|KSSP300R.1|CuttingTool|<CuttingTool>...

This form updates the asset id KSSP300R.1 for a cutting tool with the text at the end. For multiline assets, use the keyword --multiline-- with a following unique string as follows:

	2012-02-21T23:59:33.460470Z|@ASSET@|KSSP300R.1|CuttingTool|--multiline--0FED07ACED
	<CuttingTool>
	...
	</CuttingTool>
	--multiline--0FED07ACED

The terminal text must appear on the first position after the last line of text. The adapter can also remove assets (1.3) by sending a @REMOVE_ASSET@ with an asset id:

2012-02-21T23:59:33.460470Z|@REMOVE_ASSET@|KSSP300R.1

Or all assets can be removed in one shot for a certain asset type:

2012-02-21T23:59:33.460470Z|@REMOVE_ALL_ASSETS@|CuttingTool

Partial updates to assets is also possible by using the @UPDATE_ASSET@ key, but this will only work for cutting tools. The asset id needs to be given and then one of the properties or measurements with the new value for that entity. For example to update the overall tool length and the overall diameter max, you would provide the following:

2012-02-21T23:59:33.460470Z|@UPDATE_ASSET@|KSSP300R.1|OverallToolLength|323.64|CuttingDiameterMax|76.211

MQTT JSON Ingress Protocol Version 2.0

In general the data format is {"timestamp": "YYYY-MM-DDThh:mm:ssZ","dataItemId":"value", "dataItemId":{"key1":"value1", ..., "keyn":"valuen}}

NOTE: See the standard for the complete description of the fields for the data item representations below.

A simple set of events and samples will look something like this:

{
	"timestamp": "2023-11-06T12:12:44Z",			//Time Stamp
	"tempId": 22.6,								//Temperature
	"positionId": 1002.345,						//X axis position
	"executionId": "ACTIVE"						//Execution state
}

A CONDITION requires the key to be the dataItemId and requires the 6 fields as shown in the example below

{
	"timestamp": "2023-11-06T12:12:44Z",
	"dataItemId": {
		"level": "fault",
		"conditionId":"ac324",
		"nativeSeverity": "1000",
		"qualifier": "HIGH",
		"nativeCode": "ABC",
		"message": "something went wrong"
	}
}

A MESSAGE requires the key to be the dataItemId and requires the nativeCode field as shown in the example below

{
	"timestamp": "2023-11-06T12:12:44Z",
	"messsageId": {
		"nativeCode": "ABC",
		"message": "something went wrong"
	}
}

The TimeSeries REPRESENTATION requires the key to be the dataItemId and requires 2 fields "count" and "values" and 1 to n comma delimited values.

NOTE: The "frequency" field is optional.

{
	"timestamp": "2023-11-06T12:12:44Z",
	"timeSeries1": {
		"count": 10,
		"frequency": 100,
		"values": [1,2,3,4,5,6,7,8,9,10]
	}
}

The DataSet REPRESENTATION requires the the dataItemId as the key and the "values" field. It may also have the optional "resetTriggered" field.

{
{
	"timestamp": "2023-11-09T11:20:00Z",
	"dataSetId": {
		"key1": 123,
		"key2": 456,
		"key3": 789
	}
}

Example with the optional "resetTriggered" filed:

{
	"timestamp": "2023-11-09T11:20:00Z",
	"cncregisterset1": {
		"resetTriggered": "NEW",
		"value": {"r1":"v1", "r2":"v2", "r3":"v3" }
	}
}

The Table REPRESENTATION requires the the dataItemId as the key and the "values" field. It may also have the optional "resetTriggered" field.

{
	"timestamp":"2023-11-06T12:12:44Z",
	"tableId":{
		"row1":{
		"cell1":"Some Text",
		"cell2":3243
		},
		"row2": {
		"cell1":"Some Other Text",
		"cell2":243        
		}      
	}
}

Example with the optional resetTriggered field:

{
	"timestamp": "2023-11-09T11:20:00Z",
	"a1": {
		"resetTriggered": "NEW",
		"value": {
			"r1": {
				"k1": 123.45,
				"k3": 6789
			},
			"r2": null
		}
	}
}

Adapter Commands

There are a number of commands that can be sent as part of the adapter stream over the SHDR port connection. These change some dynamic elements of the device information, the interpretation of the data, or the associated default device. Commands are given on a single line starting with an asterisk * as the first character of the line and followed by a : . They are as follows:

  • Specify the Adapter Software Version the adapter supports:

    * adapterVersion: <version>

  • Set the calibration in the device component of the associated device:

    * calibration: XXX

  • Tell the agent that the data coming from this adapter requires conversion:

    * conversionRequired: <yes|no>

  • Set the description in the device header of the associated device:

    * description: XXX

  • Specify the default device for this adapter. The device can be specified as either the device name or UUID:

    * device: <uuid|name>

  • Tell the agent to load a new device XML model:

    * devicemodel: <deviceXML>

  • Set the manufacturer in the device header of the associated device:

    * manufacturer: XXX

  • Specify the MTConnect Version the adapter supports:

    * mtconnectVersion: <version>

  • Set the nativeName in the device component of the associated device:

    * nativeName: XXX

  • Tell the agent that the data coming from this adapter would like real-time priority:

    * realTime: <yes|no>

  • Tell the agent that the data coming from this adapter is specified in relative time:

    * relativeTime: <yes|no>

  • Set the serialNumber in the device header of the associated device:

    * serialNumber: XXX

  • Specify the version of the SHDR protocol delivered by the adapter. See ShdrVersion above:

    * shdrVersion: <version>

  • Set the station in the device header of the associated device:

    * station: XXX

  • Set the uuid in the device header of the associated device if preserveUuid = false:

    * uuid: XXX

Any other command will be logged as a warning.

Heartbeat Protocol

The agent and the adapter have a heartbeat that makes sure each is responsive to properly handle disconnects in a timely manner. The Heartbeat frequency is set by the adapter and honored by the agent. When the agent connects to the adapter, it first sends a * PING and then expects the response * PONG <timeout> where <timeout> is specified in milliseconds. So if the following communications are given:

Agent:

* PING

Adapter:

* PONG 10000

This indicates that the adapter is expecting a PING every 10 seconds and if there is no PING, in 2x the frequency, then the adapter should close the connection. At the same time, if the agent does not receive a PONG within 2x frequency, then it will close the connection. If no PONG response is received, the agent assumes the adapter is incapable of participating in heartbeat protocol and uses the legacy time specified above.

Just as with the SHDR protocol, these messages must end with an LF (ASCII 10) or CR-LF (ASCII 15 followed by ASCII 10).

HTTP PUT/POST Method of Uploading Data

There are two configuration settings mentioned above: AllowPut and AllowPutFrom. AllowPut alone will allow any process to use HTTP POST or PUT to send data to the agent and modify values. To restrict this to a limited number of machines, you can list the IP Addresses that are allowed to POST data to the agent.

An example would be:

AllowPut = yes
AllowPutFrom = 192.168.1.72, 192.168.1.73

This will allow the two machines to post data to the MTConnect agent. The data can be either data item values or assets. The primary use of this capability is uploading assets from a process or even the command line using utilities like curl. I'll be using curl for these examples.

For example, with curl you can use the -d option to send data to the server. The data will be in standard form data format, so all you need to do is to pass the <data_item_name>=<data_item_value> to set the values, as follows:

curl -d 'avail=AVAILABLE&program_1=XXX' 'http://localhost:5000/ExampleDevice'

By specifying the device at the end of the URL, you tell the agent which device to use for the POST. This will set the availability tag to AVAILABLE and the program to XXX:

<Availability dataItemId="dtop_3" timestamp="2015-05-18T18:20:12.278236Z" name="avail" sequence="65">AVAILABLE</Availability>
...
<Program dataItemId="path_51" timestamp="2015-05-18T18:20:12.278236Z" name="program_1" sequence="66">XXX</Program>

The full raw data being passed over looks like this:

=> Send header, 161 bytes (0xa1)
0000: POST /ExampleDevice HTTP/1.1
001e: User-Agent: curl/7.37.1
0037: Host: localhost:5000
004d: Accept: */*
005a: Content-Length: 29
006e: Content-Type: application/x-www-form-urlencoded
009f: 
=> Send data, 29 bytes (0x1d)
0000: avail=AVAILABLE&program_1=XXX
== Info: upload completely sent off: 29 out of 29 bytes
== Info: HTTP 1.0, assume close after body
<= Recv header, 17 bytes (0x11)
0000: HTTP/1.0 200 OK
<= Recv header, 20 bytes (0x14)
0000: Content-Length: 10
<= Recv header, 24 bytes (0x18)
0000: Content-Type: text/xml
<= Recv header, 2 bytes (0x2)
0000: 
<= Recv data, 10 bytes (0xa)
0000: <success/>
>== Info: Closing connection 0

This is using the --trace - to dump the internal data. The response will be a simple <success/> or <fail/>.

Any data item can be set in this fashion. Similarly conditions are set using the following syntax:

curl -d 'system=fault|XXX|1|LOW|Feeling%20low' 'http://localhost:5000/ExampleDevice'

One thing to note, the data and values are URL encoded, so the space needs to be encoded as a %20 to appear correctly.

<Fault dataItemId="controller_46" timestamp="2015-05-18T18:24:48.407898Z" name="system" sequence="67" nativeCode="XXX" nativeSeverity="1" qualifier="LOW" type="SYSTEM">Feeling Low</Fault>

Assets are posted in a similar fashion. The data will be taken from a file containing the XML for the content. The syntax is very similar to the other requests:

curl -d @B732A08500HP.xml 'http://localhost:5000/asset/B732A08500HP.1?device=ExampleDevice&type=CuttingTool'

The @... uses the named file to pass the data and the URL must contain the asset id and the device name as well as the asset type. If the type is CuttingTool or CuttingToolArchetype, the data will be parsed and corrected if properties are out of order as with the adapter. If the device is not specified and there are more than one device in this adapter, it will cause an error to be returned.

Programmatically, send the data as the body of the POST or PUT request as follows. If we look at the raw data, you will see the data is sent over verbatim as follows:

=> Send header, 230 bytes (0xe6)
0000: POST /asset/B732A08500HP.1?device=ExampleDevice&type=CuttingTool
0040:  HTTP/1.1
004b: User-Agent: curl/7.37.1
0064: Host: localhost:5000
007a: Accept: */*
0087: Content-Length: 2057
009d: Content-Type: application/x-www-form-urlencoded
00ce: Expect: 100-continue
00e4: 
== Info: Done waiting for 100-continue
=> Send data, 2057 bytes (0x809)
0000: (file data sent here, see below...)
== Info: HTTP 1.0, assume close after body
<= Recv header, 17 bytes (0x11)
0000: HTTP/1.0 200 OK
<= Recv header, 20 bytes (0x14)
0000: Content-Length: 10
<= Recv header, 24 bytes (0x18)
0000: Content-Type: text/xml
<= Recv header, 2 bytes (0x2)
0000: 
<= Recv data, 10 bytes (0xa)
0000: <success/>
<success/>== Info: Closing connection 0

The file that was included looks like this:

<CuttingTool serialNumber="1 " toolId="B732A08500HP" timestamp="2011-05-11T13:55:22" assetId="B732A08500HP.1" manufacturers="KMT">
	<Description>
		Step Drill KMT, B732A08500HP Grade KC7315
		Adapter KMT CV50BHPVTT12M375
	</Description>
	<CuttingToolLifeCycle>
		<CutterStatus><Status>NEW</Status></CutterStatus>
		<ProcessSpindleSpeed nominal="5893">5893</ProcessSpindleSpeed>
		<ProcessFeedRate nominal="2.5">2.5</ProcessFeedRate>
		<ConnectionCodeMachineSide>CV50 Taper</ConnectionCodeMachineSide>
		<Measurements>
			<BodyDiameterMax code="BDX">31.8</BodyDiameterMax>
			<BodyLengthMax code="LBX" nominal="120.825" maximum="126.325" minimum="115.325">120.825</BodyLengthMax>
			<ProtrudingLength code="LPR" nominal="155.75" maximum="161.25" minimum="150.26">158.965</ProtrudingLength>
			<FlangeDiameterMax code="DF" nominal="98.425">98.425</FlangeDiameterMax>
			<OverallToolLength nominal="257.35" minimum="251.85" maximum="262.85" code="OAL">257.35</OverallToolLength>
		</Measurements>
		<CuttingItems count="2">
			<CuttingItem indices="1" manufacturers="KMT" grade="KC7315">
				<Measurements>
					<CuttingDiameter code="DC1" nominal="8.5" maximum="8.521" minimum="8.506">8.513</CuttingDiameter>
					<StepIncludedAngle code="STA1" nominal="90" maximum="91" minimum="89">89.8551</StepIncludedAngle>
					<FunctionalLength code="LF1" nominal="154.286" minimum="148.786" maximum="159.786">157.259</FunctionalLength>
					<StepDiameterLength code="SDL1" nominal="9">9</StepDiameterLength>
					<PointAngle code="SIG" nominal="135" minimum="133" maximum="137">135.1540</PointAngle>
				</Measurements>
			</CuttingItem>
			<CuttingItem indices="2" manufacturers="KMT" grade="KC7315">
				<Measurements>
					<CuttingDiameter code="DC2" nominal="12" maximum="12.011" minimum="12">11.999</CuttingDiameter>
					<FunctionalLength code="LF2" nominal="122.493" maximum="127.993" minimum="116.993">125.500</FunctionalLength>
					<StepDiameterLength code="SDL2" nominal="9">9</StepDiameterLength>
				</Measurements>
			</CuttingItem>
		</CuttingItems>
	</CuttingToolLifeCycle>
</CuttingTool>

An example in ruby is as follows:

> require 'net/http'
=> true
> h = Net::HTTP.new('localhost', 5000)
=> #<Net::HTTP localhost:5000 open=false>
> r = h.post('/asset/B732A08500HP.1?type=CuttingTool&device=ExampleDevice', File.read('B732A08500HP.xml'))
=> #<Net::HTTPOK 200 OK readbody=true>
> r.body
=> "<success/>"

Building the agent

Overview

The agent build is dependent on the following utilities:

  • C++ Compiler compliant with C++ 17
  • git is optional but suggested to download source and update when changes occur
  • cmake for build generator and testing
  • python 3 and pip to support conan for dependency and package management
  • ruby and rake for mruby to support building the embedded scripting engine [not required if -o with_ruby=False]

Conan MTConnect Options (set using -o <option>=<value>)

  • agent_prefix: Prefix the agent and agent_lib executable. For example -o agent_prefix=mtc create mtcagent.exe and mtcagent_lib.lib

    default: ''

  • cpack: At the end of the build, run cpack to create a deployable package. By default it will go in the build direct, see cpack_destination to change the default location. Values: True or False.

    default: False

  • development: Create a build environment suitable for developemnt. Changes the test_package subdirectory by including it as part of the library build for easier debugging on IDEs and integrated build debug environments. Values: True or False.

    default: False

  • fPIC: Enables Position Independent Code on *NIX platforms allowing the machine code to be dynamically relocate on load. Values: True or False.

    default: True

  • shared: Specifies if the build will create shared libraries (.dll/.so/.dylib) or static libraries. Also makes dependent libraries dynamic as well. Packaging picks up all dependent libraries when creating the ZIP. This is useful when creating plugins since there is less duplication of dependent code. Values: True or False.

    default: False

  • winver: For windows, version of the minimum target operating system version. Defaults to Windows Vista.

    default: 0x600

  • with_docs: Enable generation of MTConnect Agent library documentation using doxygen. If true, will build the use conan to build doxygen if it is not installed. Values: True or False.

    default: False

  • with_ruby: Enable mruby extensions for dynamic scripting. Values: True or False.

    default: True

  • without_ipv6: Disable IPV6 support when building on operating systems that disable IPV6 services. Some docker images disable IPV6. Values: True or False.

    default: False

  • cpack_destination: The destination directory for the package

    default: Package build directory

  • cpack_name: The name of the package generated by cpack

    default: Default package name: agent{version}{OS}

  • cpack_generator:

    default: ZIP for windows and TGZ for *NIX

Conan useful settings (set using -s <setting>=<value>)

  • build_type: Changes the debug or release build type. Values: Release, Debug, RelWithDebInfo, and MinSizeRel. See CMake documentation for explanations.

    default: Release

Conan useful configurations (set using -c <config>=<value>)

  • tools.build:skip_test: Stops conan from running the tests. Test package will still build. To disable tests from building, use -tf "" or --testfolder= to skip the building of tests.

    default: False

  • tools.build:jobs: Sets the number of concurrent processes used in the build. If the machine runs out of resources, reduce the number of concurrent processes.

    default: number of processes

Building on Windows

The MTConnect Agent uses the conan package manager to install dependencies:

python 3 and Conan Package Manager Downloads

Download the Windows installer for your platform and run the installer.

You also need git and ruby if you want to embed mruby.

CMake is installed as part of Visual Studio. If you are using Visual Studio for the build, use the bundled version. Otherwise download from CMake CMake.

Setting up build

Install dependencies from the downloads above. Make sure python, ruby, and cmake are in your path.

pip install --upgrade pip
pip install conan

Clone the agent to another directory:

git clone https://github.com/mtconnect/cppagent.git

To build for 64 bit Windows

The following 64 and 32 bit builds will create the zip package in the directory where the repository was cloned. The build will occur in the .conan2 directory of the user's home directory.

Make sure to setup the environment:

"C:\Program Files (x86)\Microsoft Visual Studio\2019\Professional\VC\Auxiliary\Build\vcvars64.bat"

or

"C:\Program Files (x86)\Microsoft Visual Studio\2019\Community\VC\Auxiliary\Build\vcvars64.bat"
conan create cppagent -pr cppagent/conan/profiles/vs64 --build=missing -o cpack=True -o zip_destination=.

To build for 32 bit Windows

"C:\Program Files (x86)\Microsoft Visual Studio\2019\Professional\VC\Auxiliary\Build\vcvars32.bat"

or

"C:\Program Files (x86)\Microsoft Visual Studio\2019\Community\VC\Auxiliary\Build\vcvars32.bat"
conan create cppagent -pr cppagent/conan/profiles/vs32 --build=missing -o cpack=True -o zip_destination=.

*NIX Builds

The minimum memory (main + swap) when building with on CPU is 3GB. Less than that will likely cause the build to fail.

If the build runs out of resources, there are two options, you can add swap or set the following command line option:

-c tools.build:jobs=1

to instruct conan to not parallelize the builds. Some of the modules that include boost beast require significant resources to build.

Building on Ubuntu on 20.04 LTS

Setup the build

sudo apt install -y build-essential cmake gcc-11 g++-11 python3 python3-pip autoconf automake ruby ruby rake 
python3 -m pip install conan
echo 'export PATH=$HOME/.local/bin:$PATH' >> .bashrc

Download the source

git clone https://github.com/mtconnect/cppagent.git

Build the agent

conan create cppagent -pr cppagent/conan/profiles/gcc --build=missing

Building on Mac OS

Install brew and xcode command line tools

/bin/bash -c "$(curl -fsSL https://raw.githubusercontent.com/Homebrew/install/HEAD/install.sh)"
xcode-select —install

Setup the build

brew install git
brew install cmake
pip3 install conan

Download the source

git clone https://github.com/mtconnect/cppagent.git

Build the agent

conan create cppagent -pr cppagent/conan/profiles/macos --build=missing

Generate an xcode project for debugging

conan build . -pr conan/profiles/xcode -s build_type=Debug --build=missing -o development=True

Building on Fedora Alpine

As Root

apk add g++ python3 cmake git linux-headers make perl ruby
gem install rake

python3 -m ensurepip
python3 -m pip install --upgrade pip

As the user

export PATH=~/.local/bin:$PATH
pip3 install conan	
git clone https://github.com/mtconnect/cppagent.git

Build the agent

conan create cppagent -pr cppagent/conan/profiles/gcc --build=missing

For some examples, see the CI/CD workflows in .github/workflows/build.yml

Creating Test Certifications (see resources gen_certs shell script)

This section assumes you have installed openssl and can use the command line. The subject of the certificate is only for testing and should not be used in production. This section is provided to support testing and verification of the functionality. A certificate provided by a real certificate authority should be used in a production process.

NOTE: The certificates must be generated with OpenSSL version 1.1.1 or later. LibreSSL 2.8.3 is not compatible with more recent version of SSL on raspian (Debian).

Server Creating self-signed certificate chain

Create Signing authority key and certificate

openssl req -x509 -nodes -sha256 -days 3650 -newkey rsa:3072 -keyout rootca.key -out rootca.crt -subj "/C=US/ST=State/L=City/O=Your Company, Inc./OU=IT/CN=serverca.org"

User Key

openssl genrsa -out user.key 3072

Signing Request

openssl req -new -sha256 -key user.key -out user.csr -subj "/C=US/ST=State/L=City/O=Your Company, Inc./OU=IT/CN=user.org"

User Certificate using root signing certificate

openssl x509 -req -in user.csr -CA rootca.crt -CAkey rootca.key -CAcreateserial -out user.crt -days 3650

Create DH Parameters

openssl dhparam -out dh2048.pem 3072

Verify

openssl verify -CAfile rootca.crt rootca.crt
openssl verify -CAfile rootca.crt user.crt

Client Certificate

Create Signing authority key

openssl req -x509 -nodes -sha256 -days 3650 -newkey rsa:3072 -keyout clientca.key -out clientca.crt -subj "/C=US/ST=State/L=City/O=Your Company, Inc./OU=IT/CN=clientca.org"

Create client key

openssl genrsa -out client.key 3072

Create client signing request

openssl req -new -key client.key -out client.csr -subj "/C=US/ST=State/L=City/O=Your Company, Inc./OU=IT/CN=client.org"

Create Client Certificate

For client.cnf

basicConstraints = CA:FALSE
nsCertType = client, email
nsComment = "OpenSSL Generated Client Certificate"
subjectKeyIdentifier = hash
authorityKeyIdentifier = keyid,issuer
keyUsage = critical, nonRepudiation, digitalSignature, keyEncipherment
extendedKeyUsage = clientAuth, emailProtection

Create the cert

openssl x509 -req -in client.csr -CA clientca.crt -CAkey clientca.key -out client.crt -CAcreateserial -days 3650 -sha256 -extfile client.cnf

Verify

openssl verify -CAfile clientca.crt clientca.crt
openssl verify -CAfile clientca.crt client.crt

Docker

See demo or docker