Java(FX) control software for the Waterkotte Resümat CD4

License

Notifications You must be signed in to change notification settings

mwllgr/java-wtkcontrol

Repository files navigation

Java(FX) control software for the Waterkotte Resümat CD4

About this project

This program allows you to control and monitor a Waterkotte Resümat heating controller via your PC.
It uses the RS232 serial port of the Resümat controller.

Disclaimer

This is not an official software.
Do not set any values if the corresponding readings don't match the displayed data on the control unit itself or if any other readings are not correct! I'm not responsible for any damage!

Running it

Download the release file (wtkcontrol-1.3.jar) from https://github.com/mwllgr/java-wtkcontrol/releases/tag/v1.3.0 and run it:

java -jar wtkcontrol-1.3.jar

Start by selecting an address file and opening the serial port - you might have enter the device name manually (e.g. COM1 or ttyUSB0).
Java version >= 11 is required to run the file.

CLI mode

You can run the program without a GUI by using the parameter --no-gui with an appended --port <device>.
When an --address-list <file> is not given, the file address-list.csv is used.

Only reading every address value is possible in "read mode" right now. You'd have to use a different CSV file if you only want to read specific values.

Reading all values

Example:

java -jar wtkcontrol-1.3.jar --no-gui --port /dev/ttyUSB0

Output example:

Messbeginn-Datum=20.04.19
Hz-Messergebnis=4880.2
Mess-Reset=0
KomprBeginn-Zeit=01:01:01
KomprBetrStunden=43935.9
Unterbrechungen=00000000

Writing/changing a value

Example:

java -jar wtkcontrol-1.3.jar --no-gui --port /dev/ttyUSB0 --write Ww-Temp-Soll --value 49.3

Output example:

ACK received!

Available parameters

The following parameters do not control any GUI elements and are only working when the program is started in --no-gui mode!

Parameter Description Required Default
--no-gui Prevents starting the application in GUI mode Yes -
--port <device> Serial port device, e.g. COM1 or /dev/ttyUSB0 Yes -
--address-list <file> Specifies the comma-separated address list - address-list.csv
--logger Only used in read mode: Saves the received values into wtk logger-dd-MM-yyyy_hh-mm-ss.csv before the application exits - -
--write <name> Enables write mode: Requires --value, writes to field named from CSV - -
--value <data> Requires --write, has to be in a valid format/range With --write -
--wakeup Sends a wake-up command to the heating controller - -
--time-sync Sends a command to sync the RTC of the controller with the local date and time - -
--help Shows the CLI help - -

Exit codes

Code Description
1 General error
10 Missing parameter or parameter value
11 Serial port (communication) error
12 File error, e.g. address file not found
13 Field for read/write operation not found in address file
14 Field for write operation is read-only
15 Validation error: Value has invalid format or is not in a valid range
16 Address list malformed (e.g. invalid data type)

Documentation

A documentation for the GUI and the protocol is available in PDF only (school requirement).
You can check it out here: WtkControl_mwllgr.pdf

As the main business area for this specific model is Germany and Austria, the program UI is written in German.

Protocol description

An extended description of the protocol is available at fhem-waterkotte-resuemat-cd4.

Screenshots

Main window

WtkControl main window