Skip to content

Commit

Permalink
InhibitWhenLuks: allow upgrades for LUKS2 bound to Clevis TPM2 token
Browse files Browse the repository at this point in the history
So far, upgrades with encrypted drives were not supported. Encrypted
drives require interactively typing unlock passphrases, which is not
suitable for automatic upgrades using Leapp. We add a feature, where
systems with all drives configured with automatic unlock method can be
upgraded.

Currently, we only support drives configured with Clevis/TPM2 token,
because networking is not configured during Leapp upgrade (excluding
NBDE).

We consume LuksDumps message to decide whether the upgrade process
should be inhibited. If there is at least one LUKS2 device without
Clevis TPM2 binding, we inhibit the upgrade because we cannot tell if
the device is not a part of a more complex storage stack and the failure
to unlock the device migt cause boot problem.

Co-authored-by: Petr Stodůlka <[email protected]>
  • Loading branch information
danzatt and pirat89 committed Nov 4, 2024
1 parent 266c249 commit ad241f7
Show file tree
Hide file tree
Showing 3 changed files with 329 additions and 42 deletions.
38 changes: 11 additions & 27 deletions repos/system_upgrade/common/actors/inhibitwhenluks/actor.py
Original file line number Diff line number Diff line change
@@ -1,40 +1,24 @@
from leapp import reporting
from leapp.actors import Actor
from leapp.models import CephInfo, StorageInfo
from leapp.reporting import create_report, Report
from leapp.libraries.actor.inhibitwhenluks import check_invalid_luks_devices
from leapp.models import CephInfo, LuksDumps, StorageInfo, TargetUserSpaceUpgradeTasks, UpgradeInitramfsTasks
from leapp.reporting import Report
from leapp.tags import ChecksPhaseTag, IPUWorkflowTag


class InhibitWhenLuks(Actor):
"""
Check if any encrypted partitions is in use. If yes, inhibit the upgrade process.
Check if any encrypted partitions are in use and whether they are supported for the upgrade.
Upgrading system with encrypted partition is not supported.
Upgrading EL7 system with encrypted partition is not supported (but ceph OSDs).
For EL8+ it's ok if the discovered used encrypted storage has LUKS2 format
and it's bounded to clevis-tpm2 token (so it can be automatically unlocked
during the process).
"""

name = 'check_luks_and_inhibit'
consumes = (StorageInfo, CephInfo)
produces = (Report,)
consumes = (CephInfo, LuksDumps, StorageInfo)
produces = (Report, TargetUserSpaceUpgradeTasks, UpgradeInitramfsTasks)
tags = (ChecksPhaseTag, IPUWorkflowTag)

def process(self):
# If encrypted Ceph volumes present, check if there are more encrypted disk in lsblk than Ceph vol
ceph_vol = []
try:
ceph_info = next(self.consume(CephInfo))
if ceph_info:
ceph_vol = ceph_info.encrypted_volumes[:]
except StopIteration:
pass

for storage_info in self.consume(StorageInfo):
for blk in storage_info.lsblk:
if blk.tp == 'crypt' and blk.name not in ceph_vol:
create_report([
reporting.Title('LUKS encrypted partition detected'),
reporting.Summary('Upgrading system with encrypted partitions is not supported'),
reporting.Severity(reporting.Severity.HIGH),
reporting.Groups([reporting.Groups.BOOT, reporting.Groups.ENCRYPTION]),
reporting.Groups([reporting.Groups.INHIBITOR]),
])
break
check_invalid_luks_devices()
Original file line number Diff line number Diff line change
@@ -0,0 +1,164 @@
from leapp import reporting
from leapp.libraries.common.config.version import get_source_major_version
from leapp.libraries.stdlib import api
from leapp.models import (
CephInfo,
DracutModule,
LuksDumps,
StorageInfo,
TargetUserSpaceUpgradeTasks,
UpgradeInitramfsTasks
)
from leapp.reporting import create_report

# https://red.ht/clevis-tpm2-luks-auto-unlock-rhel8
# https://red.ht/clevis-tpm2-luks-auto-unlock-rhel9
# https://red.ht/convert-to-luks2-rhel8
# https://red.ht/convert-to-luks2-rhel9
CLEVIS_DOC_URL_FMT = 'https://red.ht/clevis-tpm2-luks-auto-unlock-rhel{}'
LUKS2_CONVERT_DOC_URL_FMT = 'https://red.ht/convert-to-luks2-rhel{}'

FMT_LIST_SEPARATOR = '\n - '


def _formatted_list_output(input_list, sep=FMT_LIST_SEPARATOR):
return ['{}{}'.format(sep, item) for item in input_list]


def _at_least_one_tpm_token(luks_dump):
return any([token.token_type == "clevis-tpm2" for token in luks_dump.tokens])


def _get_ceph_volumes():
ceph_info = next(api.consume(CephInfo), None)
return ceph_info.encrypted_volumes[:] if ceph_info else []


def apply_obsoleted_check_ipu_7_8():
ceph_vol = _get_ceph_volumes()
for storage_info in api.consume(StorageInfo):
for blk in storage_info.lsblk:
if blk.tp == 'crypt' and blk.name not in ceph_vol:
create_report([
reporting.Title('LUKS encrypted partition detected'),
reporting.Summary('Upgrading system with encrypted partitions is not supported'),
reporting.Severity(reporting.Severity.HIGH),
reporting.Groups([reporting.Groups.BOOT, reporting.Groups.ENCRYPTION]),
reporting.Groups([reporting.Groups.INHIBITOR]),
])
break


def report_inhibitor(luks1_partitions, no_tpm2_partitions):
source_major_version = get_source_major_version()
clevis_doc_url = CLEVIS_DOC_URL_FMT.format(source_major_version)
luks2_convert_doc_url = LUKS2_CONVERT_DOC_URL_FMT.format(source_major_version)
summary = (
'We have detected LUKS encrypted volumes that do not meet current'
' criteria to be able to proceed the in-place upgrade process.'
' Right now the upgrade process requires for encrypted storage to be'
' in LUKS2 format configured with Clevis TPM 2.0.'
)

report_hints = []

if luks1_partitions:

summary += (
'\n\nSince RHEL 8 the default format for LUKS encryption is LUKS2.'
' Despite the old LUKS1 format is still supported on RHEL systems'
' it has some limitations in comparison to LUKS2.'
' Only the LUKS2 format is supported for upgrades.'
' The following LUKS1 partitions have been discovered on your system:{}'
.format(''.join(_formatted_list_output(luks1_partitions)))
)
report_hints.append(reporting.Remediation(
hint=(
'Convert your LUKS1 encrypted devices to LUKS2 and bind it to TPM2 using clevis.'
' If this is not possible in your case consider clean installation'
' of the target RHEL system instead.'
)
))
report_hints.append(reporting.ExternalLink(
url=luks2_convert_doc_url,
title='LUKS versions in RHEL: Conversion'
))

if no_tpm2_partitions:
summary += (
'\n\nCurrently we require the process to be non-interactive and'
' offline. For this reason we require automatic unlock of'
' encrypted devices during the upgrade process.'
' Currently we support automatic unlocking during the upgrade only'
' for volumes bound to Clevis TPM2 token.'
' The following LUKS2 devices without Clevis TPM2 token '
' have been discovered on your system: {}'
.format(''.join(_formatted_list_output(no_tpm2_partitions)))
)

report_hints.append(reporting.Remediation(
hint=(
'Add Clevis TPM2 binding to LUKS devices.'
' If some LUKS devices use still the old LUKS1 format, convert'
' them to LUKS2 prior to binding.'
)
))
report_hints.append(reporting.ExternalLink(
url=clevis_doc_url,
title='Configuring manual enrollment of LUKS-encrypted volumes by using a TPM 2.0 policy'
)
)
create_report([
reporting.Title('Detected LUKS devices unsuitable for in-place upgrade.'),
reporting.Summary(summary),
reporting.Severity(reporting.Severity.HIGH),
reporting.Groups([reporting.Groups.BOOT, reporting.Groups.ENCRYPTION]),
reporting.Groups([reporting.Groups.INHIBITOR]),
] + report_hints)


def check_invalid_luks_devices():
if get_source_major_version() == '7':
# NOTE: keeping unchanged behaviour for IPU 7 -> 8
apply_obsoleted_check_ipu_7_8()
return

luks_dumps = next(api.consume(LuksDumps), None)
if not luks_dumps:
api.current_logger().debug('No LUKS volumes detected. Skipping.')
return

luks1_partitions = []
no_tpm2_partitions = []
ceph_vol = _get_ceph_volumes()
for luks_dump in luks_dumps.dumps:
# if the device is managed by ceph, don't inhibit
if luks_dump.device_name in ceph_vol:
api.current_logger().debug('Skipping LUKS CEPH volume: {}'.format(luks_dump.device_name))
continue

if luks_dump.version == 1:
luks1_partitions.append(luks_dump.device_name)
elif luks_dump.version == 2 and not _at_least_one_tpm_token(luks_dump):
no_tpm2_partitions.append(luks_dump.device_name)

if luks1_partitions or no_tpm2_partitions:
report_inhibitor(luks1_partitions, no_tpm2_partitions)
else:
required_crypt_rpms = [
'clevis',
'clevis-dracut',
'clevis-systemd',
'clevis-udisks2',
'clevis-luks',
'cryptsetup',
'tpm2-tss',
'tpm2-tools',
'tpm2-abrmd'
]
api.produce(TargetUserSpaceUpgradeTasks(install_rpms=required_crypt_rpms))
api.produce(UpgradeInitramfsTasks(include_dracut_modules=[
DracutModule(name='clevis'),
DracutModule(name='clevis-pin-tpm2')
])
)
Loading

0 comments on commit ad241f7

Please sign in to comment.