13 changes: 7 additions & 6 deletions OpenEphys.Onix1/ConfigureHeadstage64.cs
Original file line number Diff line number Diff line change
Expand Up @@ -8,9 +8,9 @@ namespace OpenEphys.Onix1
/// Configures an ONIX headstage-64 on the specified port.
/// </summary>
/// <remarks>
/// Headstage-64 is a 1.5g serialized, multifunction headstage for small animals. This headstage is
/// designed to function with passive probes such as tetrode microdrives, silicon arrays, EEG/ECOG arrays,
/// etc. It provides the following features:
/// Headstage-64 is a 1.5g serialized, multifunction headstage designed to function with passive
/// probes such as tetrode microdrives, silicon arrays, EEG/ECOG arrays, etc. It provides the
/// following features:
/// <list type="bullet">
/// <item><description>64 analog ephys channels and 3 auxiliary channels sampled at 30 kHz per
/// channel.</description></item>
Expand All @@ -32,9 +32,10 @@ public class ConfigureHeadstage64 : MultiDeviceFactory
/// Initializes a new instance of the <see cref="ConfigureHeadstage64"/> class.
/// </summary>
/// <remarks>
/// Headstage-64 is a 1.5g serialized, multifunction headstage for small animals. This headstage is designed to function
/// with tetrode microdrives. Alternatively it can be used with other passive probes (e.g. silicon arrays, EEG/ECOG arrays,
/// etc.). It provides the following features on the headstage:
/// Headstage-64 is a 1.5g serialized, multifunction headstage designed to function with
/// tetrode microdrives. Alternatively it can be used with other passive probes (e.g.
/// silicon arrays, EEG/ECOG arrays, etc.). It provides the following features on the
/// headstage:
/// <list type="bullet">
/// <item><description>64 analog ephys channels and 3 auxiliary channels sampled at 30 kHz per channel.</description></item>
/// <item><description>A Bno055 9-axis IMU for real-time, 3D orientation tracking.</description></item>
Expand Down
8 changes: 4 additions & 4 deletions OpenEphys.Onix1/ConfigureHeadstageNric1384.cs
Original file line number Diff line number Diff line change
Expand Up @@ -8,10 +8,10 @@ namespace OpenEphys.Onix1
/// Configures a Nric1384 headstage on the specified port.
/// </summary>
/// <remarks>
/// The Nric1384 Headstage is a 2.5g serialized, multifunction headstage for small animals built around the
/// IMEC Nric1384 bioacquisition chip. This headstage is designed to function with passive probes of the
/// user's choosing (e.g. silicon probe arrays, high-density tetrode drives, etc). It provides the
/// following features:
/// The Nric1384 Headstage is a 2.5g serialized, multifunction headstage built around the IMEC
/// Nric1384 bioacquisition chip and designed to function with passive probes of
/// the user's choosing (e.g. silicon probe arrays, high-density tetrode drives, etc). It
/// provides the following features:
/// <list type="bullet">
/// <item><description>384 analog ephys channels sampled at 30 kHz per channel and exposed via an array of
/// 12x ultra-high density Molex 203390-0323 quad-row connectors. </description></item>
Expand Down
8 changes: 4 additions & 4 deletions OpenEphys.Onix1/ConfigureHeadstageRhs2116.cs
Original file line number Diff line number Diff line change
Expand Up @@ -8,10 +8,10 @@ namespace OpenEphys.Onix1
/// Configures an ONIX Rhs2116 Headstage on the specified port.
/// </summary>
/// <remarks>
/// The Rhs2116 Headstage is a serialized headstage for small animals with 32 bi-directional channels
/// which each can be used to deliver electrical stimuli. The Rhs2116 Headstage can be used with passive
/// probes (e.g. silicon arrays, EEG/ECOG arrays, etc) using a 36-Channel Omnetics EIB. It provides the
/// following features:
/// The Rhs2116 Headstage is a serialized headstage with 32 bi-directional channels that are
/// independently configurable to record electrophysiological signals or deliver electrical
/// stimuli. The Rhs2116 Headstage can be used with passive probes (e.g. silicon arrays,
/// EEG/ECOG arrays, etc) using a 36-Channel Omnetics EIB. It provides the following features:
cjsha marked this conversation as resolved.
Show resolved Hide resolved
/// <list type="bullet">
/// <item><description>Two, synchronized Rhs2116 ICs for a combined 32 bidirectional ephys channels.</description></item>
/// <item><description>Real-time control of stimulation sequences.</description></item>
Expand Down
4 changes: 2 additions & 2 deletions OpenEphys.Onix1/ConfigureNeuropixelsV1eHeadstage.cs
Original file line number Diff line number Diff line change
Expand Up @@ -8,8 +8,8 @@ namespace OpenEphys.Onix1
/// Configures a NeuropixelsV1e headstage on the specified port.
/// </summary>
/// <remarks>
/// The NeuropixelsV1e Headstage is a 0.68g serialized, multifunction headstage for small animals. This
/// headstage is designed to function with IMEC Neuropixels V1 probes. It provides the following features:
/// The NeuropixelsV1e Headstage is a 0.68g serialized, multifunction headstage designed to
/// function with IMEC Neuropixels V1 probes. It provides the following features:
/// <list type="bullet">
/// <item><description>Support for a single IMEC Neuropixels 1.0 probe that features:
/// <list type="bullet">
Expand Down
4 changes: 2 additions & 2 deletions OpenEphys.Onix1/ConfigureNeuropixelsV1fHeadstage.cs
Original file line number Diff line number Diff line change
Expand Up @@ -8,8 +8,8 @@ namespace OpenEphys.Onix1
/// Configures a NeuropixelsV1f headstage on the specified port.
/// </summary>
/// <remarks>
/// The NeuropixelsVf Headstage is a 1g serialized, multifunction headstage for small animals. This
/// headstage is designed to function with IMEC Neuropixels V1 probes. It provides the following features:
/// The NeuropixelsVf Headstage is a 1g serialized, multifunction headstage designed to function
/// with IMEC Neuropixels V1 probes. It provides the following features:
/// <list type="bullet">
/// <item><description>Support for a 2x IMEC Neuropixels 1.0 probes, each of which features:
cjsha marked this conversation as resolved.
Show resolved Hide resolved
/// <list type="bullet">
Expand Down
4 changes: 2 additions & 2 deletions OpenEphys.Onix1/ConfigureNeuropixelsV2eBetaHeadstage.cs
Original file line number Diff line number Diff line change
Expand Up @@ -7,8 +7,8 @@ namespace OpenEphys.Onix1
/// Configures a NeuropixelsV2eBeta headstage on the specified port.
/// </summary>
/// <remarks>
/// The NeuropixelsV2e-Beta Headstage is a 0.64g serialized, multifunction headstage for small animals. This
/// headstage is designed to function with IMEC Neuropixels V2Beta probes. It provides the following features:
/// The NeuropixelsV2e-Beta Headstage is a 0.64g serialized, multifunction headstage designed to
/// function with IMEC Neuropixels V2Beta probes. It provides the following features:
cjsha marked this conversation as resolved.
Show resolved Hide resolved
/// <list type="bullet">
/// <item><description>Support for dual IMEC Neuropixels 2.0-Beta probes, each of which features:
/// <list type="bullet">
Expand Down
4 changes: 2 additions & 2 deletions OpenEphys.Onix1/ConfigureNeuropixelsV2eHeadstage.cs
Original file line number Diff line number Diff line change
Expand Up @@ -7,8 +7,8 @@ namespace OpenEphys.Onix1
/// Configures a NeuropixelsV2e headstage on the specified port.
/// </summary>
/// <remarks>
/// The NeuropixelsV2e Headstage is a 0.64g serialized, multifunction headstage for small animals. This
/// headstage is designed to function with IMEC Neuropixels V2 probes. It provides the following features:
/// The NeuropixelsV2e Headstage is a 0.64g serialized, multifunction headstage designed to
/// function with IMEC Neuropixels V2 probes. It provides the following features:
/// <list type="bullet">
/// <item><description>Support for dual IMEC Neuropixels 2.0 probes, each of which features:
/// <list type="bullet">
Expand Down
5 changes: 3 additions & 2 deletions OpenEphys.Onix1/Rhd2164Data.cs
Original file line number Diff line number Diff line change
Expand Up @@ -10,13 +10,14 @@
namespace OpenEphys.Onix1
{
/// <summary>
/// Produces a sequence of electrophysiology data frames from an Intan Rhd2164 bioacquisition chip.
/// Produces a sequence of <see cref="Rhd2164DataFrame"/> objects with data from an Intan
/// Rhd2164 bioacquisition chip.
/// </summary>
/// <remarks>
/// This data IO operator must be linked to an appropriate configuration, such as a <see
/// cref="ConfigureRhd2164"/>, using a shared <c>DeviceName</c>.
/// </remarks>
[Description("Produces a sequence of electrophysiology data frames from an Intan Rhd2164 bioacquisition chip.")]
[Description("Produces a sequence of Rhd2164DataFrame objects with data from an Intan Rhd2164 bioacquisition chip.")]
public class Rhd2164Data : Source<Rhd2164DataFrame>
{
/// <inheritdoc cref = "SingleDeviceFactory.DeviceName"/>
Expand Down
4 changes: 3 additions & 1 deletion OpenEphys.Onix1/Rhs2116Data.cs
Original file line number Diff line number Diff line change
Expand Up @@ -10,12 +10,14 @@
namespace OpenEphys.Onix1
{
/// <summary>
/// Produces a sequence of <see cref="Rhs2116DataFrame"/> objects from a NeuropixelsV2e headstage.
/// Produces a sequence of <see cref="Rhs2116DataFrame"/> objects with data from an Intan
/// Rhs2116 bioacquisition chip.
/// </summary>
/// <remarks>
/// This data IO operator must be linked to an appropriate configuration, such as a <see
/// cref="ConfigureRhs2116"/>, using a shared <c>DeviceName</c>.
/// </remarks>
[Description("Produces a sequence of Rhs2116DataFrame objects with data from an Intan Rhs2116 bioacquisition chip.")]
public class Rhs2116Data : Source<Rhs2116DataFrame>
{
/// <inheritdoc cref = "SingleDeviceFactory.DeviceName"/>
Expand Down
6 changes: 3 additions & 3 deletions OpenEphys.Onix1/Rhs2116DataFrame.cs
Original file line number Diff line number Diff line change
Expand Up @@ -29,9 +29,9 @@ public Rhs2116DataFrame(ulong[] clock, ulong[] hubClock, Mat amplifierData, Mat
/// Each row corresponds to a channel. Each column corresponds to a sample whose time is indicated by
/// the corresponding element <see cref="DataFrame.Clock"/> and <see cref="DataFrame.HubClock"/>.
/// Samples are 16-bits each and are represented using unsigned 16-bit integers. To convert to
/// micro-volts, the following equation can be used:
/// microvolts, the following equation can be used:
/// <code>
/// V_electrode (uV) = 0.195 µV × (ADC result – 32768)
/// V_electrode (µV) = 0.195 µV × (ADC result – 32768)
/// </code>
/// </remarks>
public Mat AmplifierData { get; }
Expand All @@ -43,7 +43,7 @@ public Rhs2116DataFrame(ulong[] clock, ulong[] hubClock, Mat amplifierData, Mat
/// Each row corresponds to a channel. Each column corresponds to a sample whose time is indicated by
/// the corresponding element <see cref="DataFrame.Clock"/> and <see cref="DataFrame.HubClock"/>.
/// Samples are 10-bits each and are represented using unsigned 16-bit integers. To convert to
/// micro-volts, the following equation can be used:
/// millivolts, the following equation can be used:
/// <code>
/// V_electrode (mV) = -19.23 mV × (ADC result – 512)
/// </code>
Expand Down