New Module for Solax Gen5 #1972
base: master
Are you sure you want to change the base?
Conversation
Added new Module vor Solax GEN5 Inverters with up to 3 PV Strings and up to 2 Batteries
Error: packages/modules/devices/solax/solax_gen5/inverter.py:3:1: F401 'pymodbus.constants.Endian' imported but unused
Error: packages/modules/devices/solax/solax_gen5/bat.py:36:15: E111 indentation is not a multiple of 4 Error: packages/modules/devices/solax/solax_gen5/bat.py:38:15: E111 indentation is not a multiple of 4 Error: packages/modules/devices/solax/solax_gen5/bat.py:41:15: E111 indentation is not a multiple of 4 Error: packages/modules/devices/solax/solax_gen5/bat.py:42:15: E111 indentation is not a multiple of 4 Error: packages/modules/devices/solax/solax_gen5/bat.py:44:15: E111 indentation is not a multiple of 4 Error: packages/modules/devices/solax/solax_gen5/bat.py:54:1: E305 expected 2 blank lines after class or function definition, found 1
Error: packages/modules/devices/solax/solax_gen5/counter.py:31:121: E501 line too long (138 > 120 characters) Error: packages/modules/devices/solax/solax_gen5/counter.py:46:29: E122 continuation line missing indentation or outdented Error: packages/modules/devices/solax/solax_gen5/counter.py:50:22: E124 closing bracket does not match visual indentation Warning: packages/modules/devices/solax/solax_gen5/counter.py:51:1: W293 blank line contains whitespace
Error: packages/modules/devices/solax/solax_gen5/device.py:10:121: E501 line too long (127 > 120 characters)
power_pv3 = self.__tcp_client.read_input_registers(292, ModbusDataType.UINT_16, unit=self.__modbus_id) * -1 | ||
power_temp = (power_pv1, power_pv2, power_pv3) | ||
power = sum(power_temp) | ||
exported = self.__tcp_client.read_input_registers(80, ModbusDataType.UINT_16, unit=self.__modbus_id) * 100 |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Ist beim Solax Gen5 Register 80 der Gesamt-Ertrag oder der Tagesertrag?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Das ist Tagesertrag
Oder muss hier der Gesamt-Ertrag hinein?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Das ist der Gesamtertrag.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Ok, habe ich angepasst.
Dann hätte ich gleich noch eine Frage. Im counter lese ich auch die Ströme mit aus. Die Ströme passen aber nicht 100%ig zu den berechneten (P/U) Das dürfte so wie ich es am Zähler direkt gesehen habe mit der Blindleistung zusammenhängen). Ich habe die register für die Leistung aus dem original Solax-Modul übernommen, und da wird eben rein mit der Einspeiseleistung gearbeitet Wie ist es denn mehr oder weniger gewünscht bzw. Wie wird es bei den meisten Modulen im counter gemacht? Soll der Strom einfach berechnet werden, oder sollen wenn möglich die tatsächlichen Werte verwendet werden?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Von der Regelung wird aktuell bei den WR und Speichern nur die Leistung verwendet. Du kannst aber z. B. die Ströme gerne mit auslesen. Die müssen auch nicht 1:1 zur Wirkleistung passen.
Changed exported from daily register to total register
Added new Module vor Solax GEN5 Inverters with up to 3 PV Strings and up to 2 Batteries
Adresses Issue 1919
UI: openwb-ui-settings/pull/570