Fix for false detection of THERMAL RUNAWAY #2082

Open
wants to merge 1 commit into
base: MK2
Choose a base branch
from

Commits on Aug 7, 2019

  1. Fix for false detection of THERMAL RUNAWAY

    The idea is that if it is detected that the extruder cannot keep
    the temperature, but well before reaching the alarm limit, the cooling
    fan is throttled. If that does not help, and the alarm limit is reached,
    the THERMAL RUNAWAY alarm is triggered as usual.
    This avoids the frustration of having large prints destroyed by a falsely
    detected thermal runaway when the only problem was that the cooling fan
    speed was set too high.
    egilkv committed Aug 7, 2019