.. index:: Plugins; apcups | ||
.. index:: apcups | ||
|
||
|
||
=============================== | ||
apcups | ||
=============================== | ||
|
||
|
||
.. image:: webif/static/img/plugin_logo.png | ||
:alt: plugin logo | ||
:width: 300px | ||
:height: 300px | ||
:scale: 50 % | ||
:align: left | ||
|
||
<Hier erfolgt die allgemeine Beschreibung des Zwecks des Plugins> | ||
|
||
|
||
Anforderungen | ||
============= | ||
|
||
Ein laufender ``apcupsd`` mit einem konfigurierten Netserver (NIS) ist notwendig. Dieser kann lokal oder remote laufen. | ||
Das Plugin fragt Laufzeitdaten vom apcupsd über das Hilfsprogramm ``apcaccess`` ab. Aus diesem Grund muss das ``apcups`` Package auch lokal installiert sein. | ||
Wenn der Daemon lokal installiert ist, sollte die Datei ``/etc/apcupsd/apcupsd.conf`` noch folgende Informationen beinhalten: | ||
|
||
:: | ||
|
||
NETSERVER on | ||
NISPORT 3551 | ||
NISIP 127.0.0.1 | ||
|
||
Unterstützte Geräte | ||
------------------- | ||
|
||
Aollte mit allen APC UPS Geräten funktionieren die den apcupsd unterstützen. Getestet wurde nur mit einer **smartUPS**. | ||
|
||
|
||
Konfiguration | ||
============= | ||
|
||
Die Plugin Parameter und die Informationen zur Item-spezifischen Konfiguration des Plugins sind | ||
unter :doc:`/plugins_doc/config/apcups` beschrieben. | ||
|
||
|
||
plugin.yaml | ||
----------- | ||
|
||
Zu den Informationen, welche Parameter in der ../etc/plugin.yaml konfiguriert werden können bzw. müssen, bitte | ||
bitte die Dokumentation :doc:`Dokumentation </plugins_doc/config/apcups>` lesen, die aus | ||
den Metadaten der plugin.yaml erzeugt wurde (siehe oben). | ||
|
||
items.yaml | ||
---------- | ||
|
||
Zu den Informationen, welche Attribute in der Item Konfiguration verwendet werden können bzw. müssen, bitte | ||
bitte die Dokumentation :doc:`Dokumentation </plugins_doc/config/apcups>` lesen, die aus | ||
den Metadaten der plugin.yaml erzeugt wurde (siehe oben). | ||
|
||
Es gibt nur ein einziges Attribut ``apcups``. Die Namen für den Statusabruf können über den Befehl ``apcaccess`` auf der Kommandozeile | ||
abgerufen werden. Damit wird eine Liste der Art ``Statusname : Wert`` angezeigt. | ||
|
||
Der Wert der dem ``apcups`` Item Attribut als Parameter übergeben wird ist dieser Statusname. Dem Item wird dann dieser Wert zugewiesen. | ||
|
||
:: | ||
|
||
APC : 001,050,1127 | ||
DATE : 2017-11-02 07:59:15 +0100 | ||
HOSTNAME : sh11 | ||
VERSION : 3.14.12 (29 March 2014) debian | ||
UPSNAME : UPS_IDEN | ||
CABLE : Ethernet Link | ||
DRIVER : PCNET UPS Driver | ||
UPSMODE : Stand Alone | ||
STARTTIME: 2017-11-02 07:59:11 +0100 | ||
MODEL : Smart-UPS 1400 RM | ||
STATUS : ONLINE | ||
LINEV : 227.5 Volts | ||
LOADPCT : 31.2 Percent | ||
BCHARGE : 100.0 Percent | ||
TIMELEFT : 30.0 Minutes | ||
MBATTCHG : 10 Percent | ||
MINTIMEL : 5 Minutes | ||
MAXTIME : 0 Seconds | ||
MAXLINEV : 227.5 Volts | ||
MINLINEV : 226.0 Volts | ||
OUTPUTV : 227.5 Volts | ||
SENSE : High | ||
DWAKE : 0 Seconds | ||
DSHUTD : 120 Seconds | ||
DLOWBATT : 2 Minutes | ||
LOTRANS : 208.0 Volts | ||
HITRANS : 253.0 Volts | ||
RETPCT : 0.0 Percent | ||
ITEMP : 25.6 C | ||
ALARMDEL : Low Battery | ||
BATTV : 27.7 Volts | ||
LINEFREQ : 49.8 Hz | ||
LASTXFER : Line voltage notch or spike | ||
NUMXFERS : 0 | ||
TONBATT : 0 Seconds | ||
CUMONBATT: 0 Seconds | ||
XOFFBATT : N/A | ||
SELFTEST : NO | ||
STESTI : 336 | ||
STATFLAG : 0x05000008 | ||
REG1 : 0x00 | ||
REG2 : 0x00 | ||
REG3 : 0x00 | ||
MANDATE : 08/16/00 | ||
SERIALNO : GS0034003173 | ||
BATTDATE : 06/20/15 | ||
NOMOUTV : 230 Volts | ||
NOMBATTV : 24.0 Volts | ||
EXTBATTS : 0 | ||
FIRMWARE : 162.3.I | ||
END APC : 2017-11-02 08:00:39 +0100 | ||
|
||
Das Plugin führt eine automatische Typumwandlung durch entsprechend dem verwendeten Item Typ. | ||
Bei der Umwandlung in einen numerischen Wert wird nach dem ersten Leerzeichen abgeschnitten und dann konvertiert. | ||
Aus ``235 Volt`` wird also ``235`` | ||
|
||
logic.yaml | ||
---------- | ||
|
||
Zu den Informationen, welche Konfigurationsmöglichkeiten für Logiken bestehen, bitte | ||
bitte die Dokumentation :doc:`Dokumentation </plugins_doc/config/apcups>` lesen, die aus | ||
den Metadaten der plugin.yaml erzeugt wurde (siehe oben). | ||
|
||
Funktionen | ||
---------- | ||
|
||
Zu den Informationen, welche Funktionen das Plugin bereitstellt (z.B. zur Nutzung in Logiken), bitte | ||
bitte die Dokumentation :doc:`Dokumentation </plugins_doc/config/apcups>` lesen, die aus | ||
den Metadaten der plugin.yaml erzeugt wurde (siehe oben). | ||
|
||
<Hier können bei Bedarf ausführliche Beschreibungen zu den Funktionen dokumentiert werden.> | ||
|
||
| | ||
Beispiele | ||
========= | ||
|
||
Beispiel | ||
~~~~~~~ | ||
|
||
The example below will read the keys **LINEV**, **STATUS** and | ||
**TIMELEFT** and returns their values. | ||
|
||
.. code:: yaml | ||
# items/apcups.yaml | ||
serverroom: | ||
apcups: | ||
linev: | ||
visu_acl: ro | ||
type: num | ||
apcups: linev | ||
status: | ||
# will be 'ONLINE', 'ONBATT', or in case of a problem simply empty | ||
visu_acl: ro | ||
type: str | ||
apcups: status | ||
timeleft: | ||
visu_acl: ro | ||
type: num | ||
apcups: timeleft | ||
**type** depends on the values. | ||
|
||
Status Report Fields | ||
~~~~~~~~~~~~~~~~~~~~ | ||
|
||
Due to a look into this | ||
http://apcupsd.org/manual/manual.html#configuration-examples file the | ||
meaning of the above variables are as follows | ||
|
||
:: | ||
|
||
APC | ||
Header record indicating the STATUS format revision level, the number of records that follow the APC statement, and the number of bytes that follow the record. | ||
DATE | ||
The date and time that the information was last obtained from the UPS. | ||
HOSTNAME | ||
The name of the machine that collected the UPS data. | ||
UPSNAME | ||
The name of the UPS as stored in the EEPROM or in the UPSNAME directive in the configuration file. | ||
VERSION | ||
The apcupsd release number, build date, and platform. | ||
CABLE | ||
The cable as specified in the configuration file (UPSCABLE). | ||
MODEL | ||
The UPS model as derived from information from the UPS. | ||
UPSMODE | ||
The mode in which apcupsd is operating as specified in the configuration file (UPSMODE) | ||
STARTTIME | ||
The time/date that apcupsd was started. | ||
STATUS | ||
The current status of the UPS (ONLINE, ONBATT, etc.) | ||
LINEV | ||
The current line voltage as returned by the UPS. | ||
LOADPCT | ||
The percentage of load capacity as estimated by the UPS. | ||
BCHARGE | ||
The percentage charge on the batteries. | ||
TIMELEFT | ||
The remaining runtime left on batteries as estimated by the UPS. | ||
MBATTCHG | ||
If the battery charge percentage (BCHARGE) drops below this value, apcupsd will shutdown your system. Value is set in the configuration file (BATTERYLEVEL) | ||
MINTIMEL | ||
apcupsd will shutdown your system if the remaining runtime equals or is below this point. Value is set in the configuration file (MINUTES) | ||
MAXTIME | ||
apcupsd will shutdown your system if the time on batteries exceeds this value. A value of zero disables the feature. Value is set in the configuration file (TIMEOUT) | ||
MAXLINEV | ||
The maximum line voltage since the UPS was started, as reported by the UPS | ||
MINLINEV | ||
The minimum line voltage since the UPS was started, as returned by the UPS | ||
OUTPUTV | ||
The voltage the UPS is supplying to your equipment | ||
SENSE | ||
The sensitivity level of the UPS to line voltage fluctuations. | ||
DWAKE | ||
The amount of time the UPS will wait before restoring power to your equipment after a power off condition when the power is restored. | ||
DSHUTD | ||
The grace delay that the UPS gives after receiving a power down command from apcupsd before it powers off your equipment. | ||
DLOWBATT | ||
The remaining runtime below which the UPS sends the low battery signal. At this point apcupsd will force an immediate emergency shutdown. | ||
LOTRANS | ||
The line voltage below which the UPS will switch to batteries. | ||
HITRANS | ||
The line voltage above which the UPS will switch to batteries. | ||
RETPCT | ||
The percentage charge that the batteries must have after a power off condition before the UPS will restore power to your equipment. | ||
ITEMP | ||
Internal UPS temperature as supplied by the UPS. | ||
ALARMDEL | ||
The delay period for the UPS alarm. | ||
BATTV | ||
Battery voltage as supplied by the UPS. | ||
LINEFREQ | ||
Line frequency in hertz as given by the UPS. | ||
LASTXFER | ||
The reason for the last transfer to batteries. | ||
NUMXFERS | ||
The number of transfers to batteries since apcupsd startup. | ||
XONBATT | ||
Time and date of last transfer to batteries, or N/A. | ||
TONBATT | ||
Time in seconds currently on batteries, or 0. | ||
CUMONBATT | ||
Total (cumulative) time on batteries in seconds since apcupsd startup. | ||
XOFFBATT | ||
Time and date of last transfer from batteries, or N/A. | ||
SELFTEST | ||
|
||
The results of the last self test, and may have the following values: | ||
|
||
OK: self test indicates good battery | ||
BT: self test failed due to insufficient battery capacity | ||
NG: self test failed due to overload | ||
NO: No results (i.e. no self test performed in the last 5 minutes) | ||
|
||
STESTI | ||
The interval in hours between automatic self tests. | ||
STATFLAG | ||
Status flag. English version is given by STATUS. | ||
DIPSW | ||
The current dip switch settings on UPSes that have them. | ||
REG1 | ||
The value from the UPS fault register 1. | ||
REG2 | ||
The value from the UPS fault register 2. | ||
REG3 | ||
The value from the UPS fault register 3. | ||
MANDATE | ||
The date the UPS was manufactured. | ||
SERIALNO | ||
The UPS serial number. | ||
BATTDATE | ||
The date that batteries were last replaced. | ||
NOMOUTV | ||
The output voltage that the UPS will attempt to supply when on battery power. | ||
NOMINV | ||
The input voltage that the UPS is configured to expect. | ||
NOMBATTV | ||
The nominal battery voltage. | ||
NOMPOWER | ||
The maximum power in Watts that the UPS is designed to supply. | ||
HUMIDITY | ||
The humidity as measured by the UPS. | ||
AMBTEMP | ||
The ambient temperature as measured by the UPS. | ||
EXTBATTS | ||
The number of external batteries as defined by the user. A correct number here helps the UPS compute the remaining runtime more accurately. | ||
BADBATTS | ||
The number of bad battery packs. | ||
FIRMWARE | ||
The firmware revision number as reported by the UPS. | ||
APCMODEL | ||
The old APC model identification code. | ||
END APC | ||
The time and date that the STATUS record was written. | ||
|
||
|
||
| | ||
Web Interface | ||
============= | ||
|
||
Aktuell hat das Plugin kein Webinterface | ||
|
||
Tab 1: <Name des Tabs> | ||
---------------------- | ||
|
||
<Hier wird der Inhalt und die Funktionalität des Tabs beschrieben.> | ||
|
||
.. image:: assets/webif_tab1.jpg | ||
:class: screenshot | ||
|
||
<Zu dem Tab ist ein Screenshot im Unterverzeichnis ``assets`` des Plugins abzulegen. | ||
|
||
| | ||
Version History | ||
=============== | ||
|
||
<In diesem Abschnitt kann die Versionshistorie dokumentiert werden, falls der Plugin Autor dieses möchte. | ||
Diese Abschnitt ist optional.> | ||
|
||
|