Skip to content

Honeywell HAF Series Zephyr mass flow sensors readout

Notifications You must be signed in to change notification settings

stripemsu/HoneywellFlow

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

12 Commits
 
 
 
 
 
 
 
 

Repository files navigation

HoneywellFlow

Server uses python 2

This project made for reading data from 2 Honeywell Zephyr HAF Series flow sensors and provide this data as JSON on any requests. Data logged by telegraf using httpjson requests on the same host

Hardware used: RaspberryPi 3, I2C Switch TCA9548A, HAFUHT0100L4AXT sensors

Sensors connected on Ch0 and Ch1 with 2KOhm pull-up resistors.

Install

server script expected at /srv/flow/FlowServer.py

$ chmod +x /srv/flow/FlowServer.py

put systemd script to /lib/systemd/system/flowserver.service

$ sudo systemctl daemon-reload
$ sudo systemctl start flowserver.service
$ sudo systemctl enable flowserver.service