2 changes: 2 additions & 0 deletions docs/Commands.md
Original file line number Diff line number Diff line change
Expand Up @@ -978,6 +978,7 @@ Command|Parameters
NPFiltration<a class="cmnd" id="NPFiltration"></a>|`{<state> {<speed>}}`<BR>get/set manual filtration (state = `0` or `1`, speed = `1..3`). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - manual turn filtration pump off</li><li>`1` - manual turn filtration pump on</li></ul>optional speed control is possible for non-standard filtration types:<ul><li>`1` - slow</li><li>`2` - medium</li><li>`3` - fast</li></ul>
NPFiltrationmode<a class="cmnd" id="NPFiltrationmode"></a>|`{<mode>}`<BR>get/set filtration mode (mode = `0..4` or `13`). Get if mode is omitted, otherwise set accordingly `<mode>`:<ul><li>`0` - *MANUAL*<BR>allows to turn the filtration (and all other systems that depend on it) on and off</li><li>`1` - *AUTO*<BR>allows filtering to be turned on and off according to the settings of the *MBF_PAR_TIMER_BLOCK_FILT_INT* timers.</li><li>`2` - *HEATING*<BR>similar to the AUTO mode, but includes setting the temperature for the heating function. This mode is activated only if the BF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.</li><li>`3` - *SMART*<BR>adjusts the pump operating times depending on the temperature. This mode is activated only if the MBF_PAR_TEMPERATURE_ACTIVE register is at 1.</li><li>`4` - *INTELLIGENT*<BR>performs an intelligent filtration process in combination with the heating function. This mode is activated only if the MBF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.</li><li>`13` - *BACKWASH*<BR>started when the backwash operation is activated.</ul>
NPFiltrationspeed<a class="cmnd" id="NPFiltrationspeed"></a>|`{<speed>}`<BR>(only available for non-standard filtration types)<BR>get/set manual filtration speed (speed = `1..3`)<BR>get filtration speed if `<speed>` is omitted, otherwise set new `<speed>`:<ul><li>`1` - Low</li><li>`2` - Mid</li><li>`3` - High</li></ul>
NPBoost<a class="cmnd" id="NPBoost"></a>|`{<mode>}`<BR>get/set hydrolysis/electrolysis boost mode (mode = `0..2` or `OFF`, `ON`, `REDOX`)<BR>get if mode is omitted, otherwise set accordingly `<mode>`:<ul><li>`0` or `OFF` - *Boost off*<BR>disables the boost mode</li><li>`1` or `ON` - *Boost on*<BR>enables the boost mode independent of the redox value</li><li>`2` or `REDOX` - *Boost on with Redox control*<BR>similar to ON, but with consideration of the current redox settings.</li></ul>Please note that the boost function also always switches the filtration to on.
NPTime<a class="cmnd" id="NPTime"></a>|`{<time>}`<BR>get/set device time. Get if time is omitted, otherwise set device time accordingly `<time>`:<ul><li>`0` - sync with Tasmota local time</li><li>`1` - sync with Tasmota utc time</li><li>`2..4294967295` - set time as epoch</li></ul>
NPLight<a class="cmnd" id="NPLight"></a>|`{<state> {delay}}`<BR>get/set light (state = `0..4`, delay = `5..100` in 1/10 sec). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - manual turn light off</li><li>`1` - manual turn light on</li><li>`2` - manual toggle light</li><li>`3` - switch light into auto mode according MBF_PAR_TIMER_BLOCK_LIGHT_INT settings</li><li>`4` - select light RGB LED to next program. This is normally done by power the light on (if currently off), then power off the light for a given time (delay) and power on again. The default delay is 15 (=1.5 sec).</ul>
NPpHMin<a class="cmnd" id="NPpHMin"></a>|`{<ph>}`<BR>(only available if pH module is installed)<BR>get/set pH lower limit (ph = `0..14`)<BR>get current limit if <ph> is omitted, otherwise set.
Expand All @@ -988,6 +989,7 @@ NPHydrolysis<a class="cmnd" id="NPHydrolysis"></a>|`{<level> {%}}`<BR>(only avai
NPIonization<a class="cmnd" id="NPIonization"></a>|`{<level>}`<BR>(only available if ionization control is present)<BR>get/set ionization target production level (level = `0..x`, the upper limit `x` of the range may vary depending on the MBF_PAR_ION_NOM register)<BR>get current level if <level> is omitted, otherwise set
NPChlorine<a class="cmnd" id="NPChlorine"></a>|`{<setpoint>}`<BR>(only available if free chlorine probe detector is installed)<BR>get/set chlorine set point in ppm (setpoint = `0..10`)<BR>get current set point if <setpoint> is omitted, otherwise set
NPControl<a class="cmnd" id="NPControl"></a>|<BR>Show information about system controls
NPTelePeriod<a class="cmnd" id="NPTelePeriod"></a>|`{<time>}`<BR>enables/disables auto telemetry message when NeoPool values change (time = `0` or `5..3600`).<BR>get current setting if time is omitted, otherwise set accordingly `<time>`:<ul><li>`0` - disable this function off (default), telemetry message are only reported depending on [TelePeriod](#teleperiod) setting</li><li>`5..3600` - set the minimum of seconds between two telemetry messages for NeoPool measured values (status changes for relays and settings trigger the SENSOR messages immediately, regardless of the time set)</li></ul>Hint: To get immediate telemetry messages only for status changes (relays, settings) set `<time>` higher than [TelePeriod](#teleperiod). In this case, measured sensors are reported only by [TelePeriod](Commands.md#teleperiod) setting, status changes are reported immediately.
NPOnError<a class="cmnd" id="NPOnError"></a>|`{<repeat>}`<BR>get/set auto-repeat Modbus read/write commands on error (repeat = `0..10`). Get if repeat is omitted, otherwise set accordingly `<repeat>`:<ul><li>`0` - disable auto-repeat on read/write error</li><li>`1..10` - repeat commands n times until ok</li></ul>
NPResult<a class="cmnd" id="NPResult"></a>|`{<format>}`<BR>get/set addr/data result format for read/write commands (format = `0|1`). Get if format is omitted, otherwise set accordingly `<format>`:<ul><li>`0` - output decimal numbers</li><li>`1` - output hexadecimal strings, this is the default</li></ul>
NPPHRes<a class="cmnd" id="NPPHRes"></a>|`{<digits>}`<BR>get/set number of digits in results for PH value (digits = `0..3`).
Expand Down
73 changes: 5 additions & 68 deletions docs/NeoPool.md
Original file line number Diff line number Diff line change
Expand Up @@ -247,7 +247,7 @@ Hydrolysis.Runtime.Pol2|(String) Cell runtime for polarization 2
Hydrolysis.Runtime.Changes|(Int) Number of polarization changes
Hydrolysis.State|(String) Cell state:<BR>`OFF` = Cell inactive<BR>`FLOW` = Cell water flow alarm<BR>`POL1` = Cell polarization 1 active<BR>`POL2` = Cell polarization 2 active
Hydrolysis.Cover|(Bool) Cover signal input:<BR>`0` = Cover input inactive<BR>`1` = Cover input active
Hydrolysis.Boost|(Int) Boost mode state:<BR>`0` = Boost mode inactive<BR>`1` = Boost mode active with redox control<BR>`2` = Boost mode active without redox control
Hydrolysis.Boost|(Int) Boost mode state:<BR>`0` = Boost mode inactive<BR>`1` = Boost mode active<BR>`2` = Boost mode active with redox control
Hydrolysis.Low|(Bool) Hydrolysis low alarm:<BR>`0` = No alarm<BR>`1` = Hydrolysis cannot reach the set point
Filtration.State|(Int) Filtration pump state:<BR>`0` = Pump off<BR>`1` = Pump on
Filtration.Speed|(Int) Filtration pump speed:<BR>`1` = Low<BR>`2` = Middle<BR>`3` = High
Expand Down Expand Up @@ -313,6 +313,7 @@ Command|Parameters
NPFiltration<a id="NPFiltration"></a>|`{<state> {speed}}`<BR>get/set manual filtration (state = `0` or `1`, speed = `1..3`). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - manual turn filtration pump off</li><li>`1` - manual turn filtration pump on</li></ul>optional speed control is possible for non-standard filtration types:<ul><li>`1` - slow</li><li>`2` - medium</li><li>`3` - fast</li></ul>
NPFiltrationmode<a id="NPFiltrationmode"></a>|`{<mode>}`<BR>get/set filtration mode (mode = `0..4` or `13`). Get if mode is omitted, otherwise set accordingly `<mode>`:<ul><li>`0` - *MANUAL*<BR>allows to turn the filtration (and all other systems that depend on it) on and off</li><li>`1` - *AUTO*<BR>allows filtering to be turned on and off according to the settings of the *MBF_PAR_TIMER_BLOCK_FILT_INT* timers.</li><li>`2` - *HEATING*<BR>similar to the AUTO mode, but includes setting the temperature for the heating function. This mode is activated only if the BF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.</li><li>`3` - *SMART*<BR>adjusts the pump operating times depending on the temperature. This mode is activated only if the MBF_PAR_TEMPERATURE_ACTIVE register is at 1.</li><li>`4` - *INTELLIGENT*<BR>performs an intelligent filtration process in combination with the heating function. This mode is activated only if the MBF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.</li><li>`13` - *BACKWASH*<BR>started when the backwash operation is activated.</ul>
NPFiltrationspeed<a id="NPFiltrationspeed"></a>|`{<speed>}`<BR>(only available for non-standard filtration types)<BR>get/set manual filtration speed (speed = `1..3`)<BR>get filtration speed if `<speed>` is omitted, otherwise set new `<speed>`:<ul><li>`1` - Low</li><li>`2` - Mid</li><li>`3` - High</li></ul>
NPBoost<a id="NPBoost"></a>|`{<mode>}`<BR>get/set hydrolysis/electrolysis boost mode (mode = `0..2` or `OFF`, `ON`, `REDOX`)<BR>get if mode is omitted, otherwise set accordingly `<mode>`:<ul><li>`0` or `OFF` - *Boost off*<BR>disables the boost mode</li><li>`1` or `ON` - *Boost on*<BR>enables the boost mode independent of the redox value</li><li>`2` or `REDOX` - *Boost on with Redox control*<BR>similar to ON, but with consideration of the current redox settings.</li></ul>Please note that the boost function also always switches the filtration to on.
NPTime<a id="NPTime"></a>|`{<time>}`<BR>get/set device time. Get if time is omitted, otherwise set device time accordingly `<time>`:<ul><li>`0` - sync with Tasmota local time</li><li>`1` - sync with Tasmota utc time</li><li>`2..4294967295` - set time as epoch</li></ul>
NPLight<a id="NPLight"></a>|`{<state> {delay}}`<BR>get/set light (state = `0..4`, delay = `5..100` in 1/10 sec). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - manual turn light off</li><li>`1` - manual turn light on</li><li>`2` - manual toggle light</li><li>`3` - switch light into auto mode according MBF_PAR_TIMER_BLOCK_LIGHT_INT settings</li><li>`4` - select light RGB LED to next program. This is normally done by power the light on (if currently off), then power off the light for a given time (delay) and power on again. The default delay is 15 (=1.5 sec).</ul>
NPpHMin<a id="NPpHMin"></a>|`{<ph>}`<BR>(only available if pH module is installed)<BR>get/set pH lower limit (ph = `0..14`)<BR>get current limit if <ph> is omitted, otherwise set.
Expand All @@ -323,6 +324,7 @@ NPHydrolysis<a id="NPHydrolysis"></a>|`{<level> {%}}`<BR>(only available if hydr
NPIonization<a id="NPIonization"></a>|`{<level>}`<BR>(only available if ionization control is present)<BR>get/set ionization target production level (level = `0..x`, the upper limit `x` of the range may vary depending on the MBF_PAR_ION_NOM register)<BR>get current level if <level> is omitted, otherwise set
NPChlorine<a id="NPChlorine"></a>|`{<setpoint>}`<BR>(only available if free chlorine probe detector is installed)<BR>get/set chlorine set point in ppm (setpoint = `0..10`)<BR>get current set point if <setpoint> is omitted, otherwise set
NPControl<a id="NPControl"></a>|<BR>Show information about system controls
NPTelePeriod<a id="NPTelePeriod"></a>|`{<time>}`<BR>enables/disables auto telemetry message when NeoPool values change (time = `0` or `5..3600`).<BR>get current setting if time is omitted, otherwise set accordingly `<time>`:<ul><li>`0` - disable this function off (default), telemetry message are only reported depending on [TelePeriod](Commands.md#teleperiod) setting</li><li>`5..3600` - set the minimum of seconds between two telemetry messages for NeoPool measured values (status changes for relays and settings trigger the SENSOR messages immediately, regardless of the time set)</li></ul>Hint: To get telemetry immediate messages only for status changes (relays, settings) set `<time>` higher than [TelePeriod](Commands.md#teleperiod). In this case, measured sensors are reported only by [TelePeriod](Commands.md#teleperiod) setting, status changes are reported immediately.
NPOnError<a id="NPOnError"></a>|`{<repeat>}`<BR>get/set auto-repeat Modbus read/write commands on error (repeat = `0..10`). Get if repeat is omitted, otherwise set accordingly `<repeat>`:<ul><li>`0` - disable auto-repeat on read/write error</li><li>`1..10` - repeat commands n times until ok</li></ul>
NPResult<a id="NPResult"></a>|`{<format>}`<BR>get/set addr/data result format for read/write commands (format = `0|1`). Get if format is omitted, otherwise set accordingly `<format>`:<ul><li>`0` - output decimal numbers</li><li>`1` - output hexadecimal strings, this is the default</li></ul>
NPPHRes<a id="NPPHRes"></a>|`{<digits>}`<BR>get/set number of digits in results for PH value (digits = `0..3`).
Expand Down Expand Up @@ -356,32 +358,6 @@ NPFiltrationmode 1
{"NPFiltrationmode":"Auto"}
```

!!! example
Enable hydrolysis boost mode without redox control

To do this, write `0x85A0` to register `MBF_BOOST_CTRL` (`0x020C`), exec, save it and notify system using register `MBF_NOTIFICATION` (`0x0110`) about changes:

```json
Backlog NPWrite 0x020C,0x85A0;NPSave;NPExec;NPWrite 0x0110,0x7F
RESULT = {"NPWrite":{"Address":"0x020C","Data":"0x85A0"}}
RESULT = {"NPSave":"Done"}
RESULT = {"NPExec":"Done"}
RESULT = {"NPWrite":{"Address":"0x0110","Data":"0x0000"}}
```

!!! example
Disable hydrolysis boost mode

To do this, write `0` to register `MBF_BOOST_CTRL` (`0x020C`), exec, save it and notify system using register `MBF_NOTIFICATION` (`0x0110`) about changes:

```json
Backlog NPWrite 0x020C,0;NPSave;NPExec;NPWrite 0x0110,0x7F
RESULT = {"NPWrite":{"Address":"0x020C","Data":"0x0000"}}
RESULT = {"NPSave":"Done"}
RESULT = {"NPExec":"Done"}
RESULT = {"NPWrite":{"Address":"0x0110","Data":"0x0000"}}
```

!!! example
Switch light relay on

Expand Down Expand Up @@ -592,11 +568,10 @@ Additional advantage is that you can also use Tasmota Timer switching Power1 (=f

The following enhancements are made using the [Berry Scripting Language](Berry) which is available on ESP32 only.

The class `NeoPoolCommands` below adds three new commands to Tasmota:
The class `NeoPoolCommands` below adds two new commands to Tasmota:

Command|Parameters
:---|:---
NPBoost<a id="NPBoost"></a>|`{<state>}`<BR>get/set boost mode (state = `0..2`). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - disable boost mode</li><li>`1` - enable boost mode (without redox control)</li><li>`2` - enable boost mode (with redox control)</li></ul>
NPAux<x\><a id="NPAux"></a>|`{<state>}`<BR>get/set auxiliary relay <x\> (state = `0..2`). Get if state is omitted, otherwise set accordingly `<state>`:<ul><li>`0` - switch off auxiliary relay</li><li>`1` - switch on auxiliary relay</li></ul>
NPVersion<a id="NPVersion"></a>|Get the firmware info as array (normally firmware version and creation date)

Expand All @@ -609,14 +584,12 @@ Store the following code into a Tasmota file by using the WebGUI "Console" / "Ma
```berry
# File: neopoolcmd.be
#
# Add commands NPBoost, NPAux and NPVersion
# Add commands NPAux and NPVersion
# Neopool definitions
MBF_POWER_MODULE_REGISTER = 0x000C
MBF_POWER_MODULE_DATA = 0x000D
var MBF_RELAY_STATE = 0x010E
var MBF_NOTIFICATION = 0x0110
var MBF_CELL_BOOST = 0x020C
var MBF_PAR_TIMER_BLOCK_AUX1_INT1 = 0x04AC
var MBF_PAR_TIMER_BLOCK_AUX2_INT1 = 0x04BB
Expand Down Expand Up @@ -677,40 +650,6 @@ class NeoPoolCommands
return res
end
#- NPBoost OFF|0|ON|1|REDOX|2
0|OFF: Switch boost off
1|ON: Switch boost on without redox control
2|REDOX: Switch boost on with redox control
-#
def NPBoost(cmd, idx, payload)
var ctrl, parm
parm = self.Param(payload, 'REDOX')
if parm != nil
if 0 == parm
ctrl = 0
elif 1 == parm
ctrl = 0x85A0
elif 2 == parm
ctrl = 0x05A0
else
tasmota.resp_cmnd_error()
return
end
tasmota.cmd(string.format("NPWrite 0x%04X,0x%04X", MBF_CELL_BOOST, ctrl))
tasmota.cmd("NPSave")
tasmota.cmd("NPExec")
tasmota.cmd(string.format("NPWrite 0x%04X,0x7F", MBF_NOTIFICATION))
else
try
ctrl = compile("return "..tasmota.cmd(string.format("NPRead 0x%04X", MBF_CELL_BOOST)).find('NPRead', json.load('{"Data": "0x0000"}')).find('Data', 0))()
except ..
tasmota.resp_cmnd_error()
return
end
end
tasmota.resp_cmnd(string.format('{"%s":"%s"}', cmd, ctrl == 0 ? self.TEXT_OFF : (ctrl & 0x8500) == 0x8500 ? self.TEXT_ON : "REDOX"))
end
#- NPAux<x> OFF|0|ON|1 t (<x> = 1..4)
0|OFF: Switch aux x off
1|ON: Switch aux x on
Expand Down Expand Up @@ -782,14 +721,12 @@ class NeoPoolCommands
self.TEXT_ON = tasmota.cmd("StateText2")['StateText2']
self.TEXT_TOGGLE = tasmota.cmd("StateText3")['StateText3']
# add commands
tasmota.add_cmd('NPBoost', / cmd, idx, payload -> self.NPBoost(cmd, idx, payload))
tasmota.add_cmd('NPAux', / cmd, idx, payload -> self.NPAux(cmd, idx, payload))
tasmota.add_cmd('NPVersion', / cmd -> self.NPVersion(cmd))
end
def deinit()
# remove commands
tasmota.remove_cmd('NPBoost')
tasmota.remove_cmd('NPAux')
tasmota.remove_cmd('NPVersion')
end
Expand Down