94 changes: 1 addition & 93 deletions Dell_iDRAC_fan_controller.sh
Original file line number Diff line number Diff line change
Expand Up @@ -4,99 +4,7 @@
# Not working in some setups : https://github.com/tigerblue77/Dell_iDRAC_fan_controller/issues/48
# set -euo pipefail

# Define global functions
# This function applies Dell's default dynamic fan control profile
function apply_Dell_fan_control_profile () {
# Use ipmitool to send the raw command to set fan control to Dell default
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null
CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile"
}

# This function applies a user-specified static fan control profile
function apply_user_fan_control_profile () {
# Use ipmitool to send the raw command to set fan control to user-specified value
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null
CURRENT_FAN_CONTROL_PROFILE="User static fan control profile ($DECIMAL_FAN_SPEED%)"
}

# Retrieve temperature sensors data using ipmitool
# Usage : retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
function retrieve_temperatures () {
if (( $# != 2 ))
then
printf "Illegal number of parameters.\nUsage: retrieve_temperatures \$IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT \$IS_CPU2_TEMPERATURE_SENSOR_PRESENT" >&2
return 1
fi
local IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=$1
local IS_CPU2_TEMPERATURE_SENSOR_PRESENT=$2

local DATA=$(ipmitool -I $IDRAC_LOGIN_STRING sdr type temperature | grep degrees)

# Parse CPU data
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
then
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
else
CPU2_TEMPERATURE="-"
fi

# Parse inlet temperature data
INLET_TEMPERATURE=$(echo "$DATA" | grep Inlet | grep -Po '\d{2}' | tail -1)

# If exhaust temperature sensor is present, parse its temperature data
if $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT
then
EXHAUST_TEMPERATURE=$(echo "$DATA" | grep Exhaust | grep -Po '\d{2}' | tail -1)
else
EXHAUST_TEMPERATURE="-"
fi
}

function enable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
}

function disable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
}

# Returns :
# - 0 if third-party PCIe card Dell default cooling response is currently DISABLED
# - 1 if third-party PCIe card Dell default cooling response is currently ENABLED
# - 2 if the current status returned by ipmitool command output is unexpected
# function is_third_party_PCIe_card_Dell_default_cooling_response_disabled() {
# THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE=$(ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x01 0x16 0x05 0x00 0x00 0x00)

# if [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 01 00 00" ]; then
# return 0
# elif [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 00 00 00" ]; then
# return 1
# else
# echo "Unexpected output: $THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" >&2
# return 2
# fi
# }

# Prepare traps in case of container exit
function gracefull_exit () {
apply_Dell_fan_control_profile
enable_third_party_PCIe_card_Dell_default_cooling_response
echo "/!\ WARNING /!\ Container stopped, Dell default dynamic fan control profile applied for safety."
exit 0
}

# Helps debugging when people are posting their output
function get_Dell_server_model () {
IPMI_FRU_content=$(ipmitool fru 2>/dev/null) # FRU stands for "Field Replaceable Unit"

SERVER_MANUFACTURER=$(echo "$IPMI_FRU_content" | grep "Product Manufacturer" | awk -F ': ' '{print $2}')
SERVER_MODEL=$(echo "$IPMI_FRU_content" | grep "Product Name" | awk -F ': ' '{print $2}')
}
source functions.sh

# Trap the signals for container exit and run gracefull_exit function
trap 'gracefull_exit' SIGQUIT SIGKILL SIGTERM
Expand Down
9 changes: 6 additions & 3 deletions Dockerfile
Original file line number Diff line number Diff line change
Expand Up @@ -6,9 +6,12 @@ RUN apt-get update

RUN apt-get install ipmitool -y

ADD Dell_iDRAC_fan_controller.sh /Dell_iDRAC_fan_controller.sh
ADD functions.sh /app/functions.sh
ADD Dell_iDRAC_fan_controller.sh /app/Dell_iDRAC_fan_controller.sh

RUN chmod 0777 /Dell_iDRAC_fan_controller.sh
RUN chmod 0777 /app/functions.sh /app/Dell_iDRAC_fan_controller.sh

WORKDIR /app

# you should override these default values when running. See README.md
#ENV IDRAC_HOST 192.168.1.100
Expand All @@ -20,4 +23,4 @@ ENV CPU_TEMPERATURE_THRESHOLD 50
ENV CHECK_INTERVAL 60
ENV DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE false

CMD ["/Dell_iDRAC_fan_controller.sh"]
CMD ["./Dell_iDRAC_fan_controller.sh"]
93 changes: 93 additions & 0 deletions functions.sh
Original file line number Diff line number Diff line change
@@ -0,0 +1,93 @@
# Define global functions
# This function applies Dell's default dynamic fan control profile
function apply_Dell_fan_control_profile () {
# Use ipmitool to send the raw command to set fan control to Dell default
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null
CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile"
}

# This function applies a user-specified static fan control profile
function apply_user_fan_control_profile () {
# Use ipmitool to send the raw command to set fan control to user-specified value
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null
CURRENT_FAN_CONTROL_PROFILE="User static fan control profile ($DECIMAL_FAN_SPEED%)"
}

# Retrieve temperature sensors data using ipmitool
# Usage : retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
function retrieve_temperatures () {
if (( $# != 2 ))
then
printf "Illegal number of parameters.\nUsage: retrieve_temperatures \$IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT \$IS_CPU2_TEMPERATURE_SENSOR_PRESENT" >&2
return 1
fi
local IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=$1
local IS_CPU2_TEMPERATURE_SENSOR_PRESENT=$2

local DATA=$(ipmitool -I $IDRAC_LOGIN_STRING sdr type temperature | grep degrees)

# Parse CPU data
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
then
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
else
CPU2_TEMPERATURE="-"
fi

# Parse inlet temperature data
INLET_TEMPERATURE=$(echo "$DATA" | grep Inlet | grep -Po '\d{2}' | tail -1)

# If exhaust temperature sensor is present, parse its temperature data
if $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT
then
EXHAUST_TEMPERATURE=$(echo "$DATA" | grep Exhaust | grep -Po '\d{2}' | tail -1)
else
EXHAUST_TEMPERATURE="-"
fi
}

function enable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
}

function disable_third_party_PCIe_card_Dell_default_cooling_response () {
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
}

# Returns :
# - 0 if third-party PCIe card Dell default cooling response is currently DISABLED
# - 1 if third-party PCIe card Dell default cooling response is currently ENABLED
# - 2 if the current status returned by ipmitool command output is unexpected
# function is_third_party_PCIe_card_Dell_default_cooling_response_disabled() {
# THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE=$(ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x01 0x16 0x05 0x00 0x00 0x00)

# if [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 01 00 00" ]; then
# return 0
# elif [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 00 00 00" ]; then
# return 1
# else
# echo "Unexpected output: $THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" >&2
# return 2
# fi
# }

# Prepare traps in case of container exit
function gracefull_exit () {
apply_Dell_fan_control_profile
enable_third_party_PCIe_card_Dell_default_cooling_response
echo "/!\ WARNING /!\ Container stopped, Dell default dynamic fan control profile applied for safety."
exit 0
}

# Helps debugging when people are posting their output
function get_Dell_server_model () {
IPMI_FRU_content=$(ipmitool fru 2>/dev/null) # FRU stands for "Field Replaceable Unit"

SERVER_MANUFACTURER=$(echo "$IPMI_FRU_content" | grep "Product Manufacturer" | awk -F ': ' '{print $2}')
SERVER_MODEL=$(echo "$IPMI_FRU_content" | grep "Product Name" | awk -F ': ' '{print $2}')
}

0 comments on commit e3ee64e