Switch RMT clock source to 1MHz REF #22
base: master
Are you sure you want to change the base?
Conversation
When using Dynamic Frequency Scaling, the APB clock changes between max_freq_mhz and min_freq_mhz. This will create errors when using the RMT peripheral for 1wire communication. Use 1Mhz REF clock source instead, it is stable even during DFS operation.
Hi @RadekHvizdos, thank you for your suggestion. This seems to me like a reasonable precursor to a proper change, however I'm not able to test this because I only have access to the original ESP32 device. Therefore I'd be happy to include something like this if you or someone else is able to write a target-specific clock selection routine and test OWB operation on all four(?) chips. Am I right in my interpretation of your table that the code would simply choose between RMT_BASECLK_REF and RMT_BASECLK_XTAL depending on the device type? Then various timing factors would need to be set based on the expected clock frequency, I assume? Can you link me to the docs that say "REF tick clock, which would be 1Mhz (not supported in this version)." please? |
Hi @DavidAntliff, Here is a link to the relevant section in the documentation: I found this forum post which clarifies the situation a little bit. The explanation makes me feel a bit better about using the REF clock: I will amend the patch with device selection code and then we can discuss it further. |
Adding logic which should use the best clock source available on each device. The capability is flagged in esp-idf's soc_caps.h file, which is different to each device family.
See the latest patch which implements the clock selection logic. When testing it I have found that:
I was only able to test with plain ESP32, but I am confident that implementing the logic will not introduce any regressions. I have tested both esp-idf 4.2 and latest 4.3. |
To easy debugging
Ok, thanks, I'll go over this as soon as I can (might be a few days at least before I get a chance). |
Hello,
When using Dynamic Frequency Scaling to reduce power consumption, the APB clock used by RMT changes between max_freq_mhz and min_freq_mhz (typicaly between 80 and 10MHz). This causes errors when using the RMT peripheral for 1wire communication.
We could use either the 1Mhz REF or 40Mhz XTAL clock sources instead, they are stable even during DFS operation:
Here is the availability of various clock sources depending on target device:
I am a bit puzzled that the documentation still states:
REF tick clock, which would be 1Mhz (not supported in this version).
When using this has clear benefits. Perhaps they just forgot to remove this?
We should probably have the clock source selected automatically based on the target device, not hard-coded. My patch is just for demonstration purposes.
What do you think?