This Homebridge plugin allows interactions with your Bosch Control Panel supporting Mode 2 integration.
- Set Panel Area arming mode (Arm, Disarm, Part on instant, Part on delay)
- Set Panel Outputs state (On, Off)
- Use Panel Points state for home automation purposes (Motion, Contact, Smoke, Leak and Carbon Monoxide)
- Get Panel Wide notifiations for Fire, Burglary, Gaz and Personnal events.
Bosch Panel | Status | Notes |
---|---|---|
B Series | Supported | |
G Series | Supported | |
GV4 | Status Pending | Firmware 2.00 and higher |
Solution 2000/3000 | Supported | Firmware >= 2.1.3 to enable subscriptions |
AMAX Series | Not Supported | Firmware 4.01 and higher |
Host
: Bosch Control Panel IP addressPort
: Bosch Control Panel Port number (defaults to 7700)Passcode
: Value as configured on your Bosch Control Panel (Automation Passcode on B, G , GV4 Panels, User Passcode on Solution 2000/3000 and AMAX Panels).Legacy Mode
: Force plugin to use first generation protocol and data pooling.
Number
: Area number on the Control Panel to be monitored by the pluginArea(s) in Scope
: Comma separated list of other Areas on your Control Panel to be monitored by this accessory. If an alarm is triggered in one of those Area, your accessory will trigger (Default value: Empty string)Passcode Follows Scope
: If selected, Arming and Disarming your accessory will also Arm or Disarm all other Areas in Scope (Default value: not selected)Show Accessory in Home App
: Show Security System Accessory in Home App
Number
: Point (Sensor) number on the Control Panel to be monitored by the plugginSensor Type
: Motion Sensor, Contact Sensor, Leak Sensor, CO Sensor or Smoke SensorShow Accessory in Home App
: Show Sensor Accessory in Home App
Number
: Output number on the Control Panel to be monitored by the plugginShow Accessory in Home App
: Show Output Accessory in Home App
If selected, Contact Sensors will be added in Home App and report panel wide Fire, Gaz, Burglary or Personnal alarms.
MasterFireAlarm
: Report panel wide Fire alarmsMasterGazAlarm
: Report panel wide Gaz alarmsMasterBurglaryAlarm
: Report panel wide Burglary alarmsMasterPersonnalAlarm
: Report panel wide Personnal alarms
Panel Confidence Message Notifications
: Show control panel keep alive notifications in log filePoints Notifications
: Show sensors state changes in log fileOutput Notifications
: Show outputs state changes in log fileArea Alarm Notifications
: Show Areas Alarms in log fileArea Arming Status Notifications
: Show Areas Arming status in log file
Whit this option enabled, the plugin will only use first generation protocol to exchange data with the panel.
- Expect longer plugin start time
- Plugin will pool the panel rather then use push notifications (subscriptions)
- Any event occuring for a very short amount of time on the panel may not be detected by the plugin in this mode (Sensor only triggering for 1 second, Output automaticaly changing state after 1 second)
The following conversions are applied between Homekit Area Arming state and Bosch Control Panel Area Arming state:
Homekit Area Arming State | Bosch Area Arming State |
---|---|
Off | Disarmed |
Away | All On Delay |
Night | Part On Instant |
Home | Part On Delay |