Create a new AQS profile for Matter Sensor #1821

Merged
merged 1 commit into from
Dec 17, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
@@ -0,0 +1,18 @@
name: aqs-temp-humidity-tvoc-meas
components:
- id: main
capabilities:
- id: airQualityHealthConcern
version: 1
- id: temperatureMeasurement
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: tvocMeasurement
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: AirQualityDetector
Original file line number Diff line number Diff line change
Expand Up @@ -162,6 +162,7 @@ local supported_profiles =
"aqs-temp-humidity-all-meas",
"aqs-temp-humidity-co2-pm25-tvoc-meas",
"aqs-temp-humidity-tvoc-level-pm25-meas",
"aqs-temp-humidity-tvoc-meas",
}

local AIR_QUALITY_MAP = {
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -200,6 +200,53 @@ local mock_device_co2 = test.mock_device.build_test_matter_device({
}
})

local mock_device_tvoc = test.mock_device.build_test_matter_device({
profile = t_utils.get_profile_definition("aqs-temp-humidity-tvoc-meas.yml"),
manufacturer_info = {
vendor_id = 0x0000,
product_id = 0x0000,
},
endpoints = {
{
endpoint_id = 0,
clusters = {
{cluster_id = clusters.Basic.ID, cluster_type = "SERVER"},
},
device_types = {
{device_type_id = 0x0016, device_type_revision = 1} -- RootNode
}
},
{
endpoint_id = 1,
clusters = {
{cluster_id = clusters.AirQuality.ID, cluster_type = "SERVER"},
{cluster_id = clusters.TemperatureMeasurement.ID, cluster_type = "SERVER"},
{cluster_id = clusters.RelativeHumidityMeasurement.ID, cluster_type = "SERVER"},
{cluster_id = clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.ID, cluster_type = "SERVER", feature_map = 1},
},
device_types = {
{device_type_id = 0x002C, device_type_revision = 1} -- Air Quality Sensor
}
}
}
})

-- create test_init functions
local function initialize_mock_device(generic_mock_device, generic_subscribed_attributes)
local subscribe_request = nil
for _, attributes in pairs(generic_subscribed_attributes) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(generic_mock_device)
else
subscribe_request:merge(attribute:subscribe(generic_mock_device))
end
end
end
test.socket.matter:__expect_send({generic_mock_device.id, subscribe_request})
test.mock_device.add_test_device(generic_mock_device)
end

local function test_init()
local subscribed_attributes = {
[capabilities.relativeHumidityMeasurement.ID] = {
Expand Down Expand Up @@ -282,19 +329,7 @@ local function test_init()
clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.LevelValue,
},
}
local subscribe_request = nil
for _, attributes in pairs(subscribed_attributes) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(mock_device)
else
subscribe_request:merge(attribute:subscribe(mock_device))
end
end
end

test.socket.matter:__expect_send({mock_device.id, subscribe_request})
test.mock_device.add_test_device(mock_device)
initialize_mock_device(mock_device, subscribed_attributes)
end
test.set_test_init_function(test_init)

Expand Down Expand Up @@ -324,19 +359,7 @@ local function test_init_common()
clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit,
},
}
local subscribe_request = nil
for _, attributes in pairs(subscribed_attributes) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(mock_device_common)
else
subscribe_request:merge(attribute:subscribe(mock_device_common))
end
end
end

test.socket.matter:__expect_send({mock_device_common.id, subscribe_request})
test.mock_device.add_test_device(mock_device_common)
initialize_mock_device(mock_device_common, subscribed_attributes)
end

local function test_init_level()
Expand Down Expand Up @@ -383,19 +406,28 @@ local function test_init_level()
clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.LevelValue,
}
}
local subscribe_request = nil
for _, attributes in pairs(subscribed_attributes) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(mock_device_level)
else
subscribe_request:merge(attribute:subscribe(mock_device_level))
end
end
end
initialize_mock_device(mock_device_level, subscribed_attributes)
end

test.socket.matter:__expect_send({mock_device_level.id, subscribe_request})
test.mock_device.add_test_device(mock_device_level)
local function test_init_tvoc()
local subscribed_attributes = {
[capabilities.airQualityHealthConcern.ID] = {
clusters.AirQuality.attributes.AirQuality
},
[capabilities.temperatureMeasurement.ID] = {
clusters.TemperatureMeasurement.attributes.MeasuredValue,
clusters.TemperatureMeasurement.attributes.MinMeasuredValue,
clusters.TemperatureMeasurement.attributes.MaxMeasuredValue
},
[capabilities.relativeHumidityMeasurement.ID] = {
clusters.RelativeHumidityMeasurement.attributes.MeasuredValue
},
[capabilities.tvocMeasurement.ID] = {
clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasuredValue,
clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit,
},
}
initialize_mock_device(mock_device_tvoc, subscribed_attributes)
end

local function test_init_co_co2()
Expand All @@ -419,35 +451,70 @@ local function test_init_co_co2()
},
}

local subscribe_request = nil
for _, attributes in pairs(attr_co) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(mock_device_co)
else
subscribe_request:merge(attribute:subscribe(mock_device_co))
end
end
end
initialize_mock_device(mock_device_co, attr_co)
initialize_mock_device(mock_device_co2, attr_co2)
end

test.socket.matter:__expect_send({mock_device_co.id, subscribe_request})
test.mock_device.add_test_device(mock_device_co)

subscribe_request = nil
for _, attributes in pairs(attr_co2) do
for _, attribute in ipairs(attributes) do
if subscribe_request == nil then
subscribe_request = attribute:subscribe(mock_device_co2)
else
subscribe_request:merge(attribute:subscribe(mock_device_co2))
end
end
-- run the profile configuration tests
local function test_aqs_device_type_do_configure(generic_mock_device, expected_profile)
test.socket.device_lifecycle:__queue_receive({generic_mock_device.id, "doConfigure"})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({generic_mock_device.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
generic_mock_device:expect_metadata_update({ profile = expected_profile })
generic_mock_device:expect_metadata_update({ provisioning_state = "PROVISIONED" })
end

test.register_coroutine_test(
"Configure should read units from device and profile change as needed",
function()
test_aqs_device_type_do_configure(mock_device, "aqs-temp-humidity-all-level-all-meas")
end
)

test.register_coroutine_test(
"Configure should read units from device and profile change to common clusters profile if applicable",
function()
test_aqs_device_type_do_configure(mock_device_common, "aqs-temp-humidity-co2-pm25-tvoc-meas")
end,
{ test_init = test_init_common }
)

test.register_coroutine_test(
"Configure should read units from device and profile change as needed",
function()
test_aqs_device_type_do_configure(mock_device_level, "aqs-temp-humidity-all-level")
end,
{ test_init = test_init_level }
)

test.register_coroutine_test(
"Configure should not catch co2, only co in the first check",
function()
test_aqs_device_type_do_configure(mock_device_co, "aqs-temp-humidity-all-meas")
test_aqs_device_type_do_configure(mock_device_co2, "aqs-temp-humidity-co2-pm25-tvoc-meas")
end,
{ test_init = test_init_co_co2 }
)

test.register_coroutine_test(
"Device should profile to aqs-temp-humidity-tvoc-meas",
function()
test_aqs_device_type_do_configure(mock_device_tvoc, "aqs-temp-humidity-tvoc-meas")
end,
{ test_init = test_init_tvoc }
)

test.socket.matter:__expect_send({mock_device_co2.id, subscribe_request})
test.mock_device.add_test_device(mock_device_co2)
end

-- run general tests
test.register_message_test(
"Temperature reports should generate correct messages",
{
Expand Down Expand Up @@ -697,98 +764,5 @@ test.register_coroutine_test(
end
)

test.register_coroutine_test(
"Configure should read units from device and profile change as needed",
function()
test.socket.device_lifecycle:__queue_receive({ mock_device.id, "doConfigure" })
test.socket.matter:__expect_send({mock_device.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
mock_device:expect_metadata_update({ profile = "aqs-temp-humidity-all-level-all-meas" })
mock_device:expect_metadata_update({ provisioning_state = "PROVISIONED" })
end
)

test.register_coroutine_test(
"Configure should read units from device and profile change to common clusters profile if applicable",
function()
test.socket.device_lifecycle:__queue_receive({ mock_device_common.id, "doConfigure" })
test.socket.matter:__expect_send({mock_device_common.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_common.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
mock_device_common:expect_metadata_update({ profile = "aqs-temp-humidity-co2-pm25-tvoc-meas" })
mock_device_common:expect_metadata_update({ provisioning_state = "PROVISIONED" })
end,
{ test_init = test_init_common }
)

test.register_coroutine_test(
"Configure should read units from device and profile change as needed",
function()
test.socket.device_lifecycle:__queue_receive({ mock_device_level.id, "doConfigure" })
test.socket.matter:__expect_send({mock_device_level.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_level.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
mock_device_level:expect_metadata_update({ profile = "aqs-temp-humidity-all-level" })
mock_device_level:expect_metadata_update({ provisioning_state = "PROVISIONED" })
end,
{ test_init = test_init_level }
)


test.register_coroutine_test(
"Configure should not catch co2, only co in the first check",
function()
test.socket.device_lifecycle:__queue_receive({ mock_device_co.id, "doConfigure" })
test.socket.matter:__expect_send({mock_device_co.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
mock_device_co:expect_metadata_update({ profile = "aqs-temp-humidity-all-meas" })
mock_device_co:expect_metadata_update({ provisioning_state = "PROVISIONED" })

test.socket.device_lifecycle:__queue_receive({ mock_device_co2.id, "doConfigure" })
test.socket.matter:__expect_send({mock_device_co2.id, clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.CarbonDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.NitrogenDioxideConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.OzoneConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.FormaldehydeConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.Pm1ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.Pm25ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.Pm10ConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.RadonConcentrationMeasurement.attributes.MeasurementUnit:read()})
test.socket.matter:__expect_send({mock_device_co2.id, clusters.TotalVolatileOrganicCompoundsConcentrationMeasurement.attributes.MeasurementUnit:read()})
mock_device_co2:expect_metadata_update({ profile = "aqs-temp-humidity-co2-pm25-tvoc-meas" })
mock_device_co2:expect_metadata_update({ provisioning_state = "PROVISIONED" })
end,
{ test_init = test_init_co_co2 }
)

-- run tests
test.run_registered_tests()