Backport: primary_path does not change its SVLAN 2024.1
backport_20241
#566
opened Nov 7, 2024 by
Alopalao
bug: request failure during deployment switch mid iteration still left the EVC active; it didn't rollback
bug
Something isn't working
epic_mef_eline_flows_error_handling
priority_low
Low priority
#555
opened Oct 31, 2024 by
viniarck
bug/usability UX: Something isn't working
tech_debt
Tech debt
Link
s status
and status_reason
of a Path
aren't always coherent
bug
#554
opened Oct 30, 2024 by
viniarck
feature: having different vlan pool allocations for UNIs and NNIs
backport_20232
backport_20241
enhancement
New feature or request
priority_critical
Critical priority
#545
opened Oct 23, 2024 by
viniarck
Redeploy of an EVC no longer fixes inconsistencies
backport_20232
backport_20241
enhancement
New feature or request
priority_critical
Critical priority
#543
opened Oct 21, 2024 by
italovalcy
Possible incorrect trace and inconsistent EVC
2025.1
Kytos-ng 2025.1
future_release
Planned for the next release
#538
opened Oct 21, 2024 by
italovalcy
Kytos 2023.2 fail to report status of the EVC correctly
backport_20232
backport_20241
bug
Something isn't working
priority_critical
Critical priority
#537
opened Oct 21, 2024 by
italovalcy
Backport 2023.2 - PR 528 - fix default collapsed path constraint options on EVC creation
#530
opened Oct 7, 2024 by
italovalcy
Double check event listener for interface link change -- seems too broad
#523
opened Oct 5, 2024 by
italovalcy
Link maintenance should reflect on the service being deactivated if no alternative path is found
#519
opened Oct 2, 2024 by
italovalcy
Multiple link downs can lead to race condition with Kytos-ng 2024.2
epic_mef_eline_consistency_v2
consistency
priority_major
Major priority
old_path
, resulting in old_path
not being properly cleared.
2024.2
#517
opened Sep 30, 2024 by
Ktmi
Reduce the number of flow related requests.
2024.2
Kytos-ng 2024.2
epic_mef_eline_flows_error_handling
#514
opened Sep 23, 2024 by
Alopalao
EVCs modified without holding lock, may lead to race conditions
2024.2
Kytos-ng 2024.2
epic_mef_eline_consistency_v2
consistency
#512
opened Sep 23, 2024 by
Ktmi
Add error status to detect when an EVC had problems
2024.2
Kytos-ng 2024.2
epic_mef_eline_flows_error_handling
#511
opened Sep 19, 2024 by
Alopalao
UI: Show that an EVC has an error
2024.2
Kytos-ng 2024.2
epic_mef_eline_flows_error_handling
#510
opened Sep 19, 2024 by
Alopalao
NoviFlow pipeline recirculation port issue resulting in lower network throughput
bug
Something isn't working
enhancement
New feature or request
future_release
Planned for the next release
priority_medium
Medium priority
#509
opened Sep 16, 2024 by
viniarck
watchdog: checking for flows of an EVC being updated more frequently than the EVC is redeployed
#506
opened Sep 5, 2024 by
italovalcy
mef_eline flow deletions is only using table 0 (use case limitations using different tables)
future_release
Planned for the next release
priority_medium
Medium priority
#499
opened Aug 23, 2024 by
viniarck
Previous Next