Notifications
You must be signed in to change notification settings - Fork 2
Galil homing routines
Wiki > The Backend System > IOCs > Motor IOCs > Galil
The galil motors can be configured to run one of the multiple homing routines. These routines are documented in the readme of the galil repository; there is extra documentation on the oscillating collimator page for those routines.
The whole consideration for the routine has to include the default header and footer for the Galil, with the following basic structure: Header Home routine for axis A Home routine for axis B Home routine for axis C Home routine for axis D Home routine for axis E Home routine for axis F Home routine for axis G Home routine for axis H Footer
Typically we then append any other code for specific functions we need after the footer, see the Galil page for more information.
The loading of the homing routines uses a macro to define the axis based on the location in the start controller setup (see Galil for more detailed information), for brevity and ease of reading this will be replaced by X throughout the descriptions below.
Further command docs can be found in the share manuals in manc2xxx.pdf
There are a number of variables used within these routines.
Variable Name | Variable Purpose |
---|---|
homeX |
Indicates that a home has been requested (1) |
hjogX |
Indicates which step of the homing routine is to be completed next |
inhomeX |
Indicates that the axis is in the process of homing |
slimflX |
Soft limit in the forward direction set for general motor use, used as an interim holder whilst homing |
slimblX |
Soft limit in the reverse direction set for general motor use, used as an interim holder whilst homing |
mlock |
? |
dpon |
? |
dvalues |
? |
homedX |
This is set to 1 before being returned as a message |
This relates to galil_Default_Header.gmc
as that relates to the home routines, and does the same task for each axis.
Set homeX = 0
, hjogX = 0
, and inhomeX = 0
The basic structure of a homing routine is as follows:
If a home has been requested (homeX = 1)
Indicate that we are in a homing routine (inhomeX = 1)
If a home has been requested (homeX = 1) and we have not yet started the homing steps (hjogX = 0)
Store the soft limits in the variables slimflX and slimblX
Set the soft limits to their maximum values
Indicate that we can go to step 1 of the homing routine (hjogX = 1)
If both limits are active and a home has been requested (homeX = 1)
Clear the home request (homeX = 0), send a message to the remote system
If we are about to start the homing routine (hjogX = 1) AND the motor is in motion AND a home has been requested (homeX = 1)
Stop the motor
Undertake appropriate homing steps
If we have completed all the homing steps (hjogX = number of steps in homing routine + 1) AND the motor isn't moving AND a home has been requested (homeX = 1) AND in certain cases that the reason for the motor stop is the appropriate value
Indicate that we are have reached the end of the homing steps (hjogX = 0)
Clear the home request (homeX = 0), send a message to the remote system
Set the homedX varirable to 1, send a message to the remote system
Else
Indicate that we are have reached the end of the homing steps (hjogX = 0)
If the home request has been cleared (homeX = 0) AND we have not completed the homing routine (inhomeX = 1)
Revert the soft limits to their original values
Indicate that we have finished the homing routine (inhomeX = 0)
If the variable mlock = 0
Set the interrupt masks to dpon and dvalues
The code to use is as follows, be sure to change the items in square brackets as appropriate, and consider the need or not for a stop code check:
NO*****************AXIS ${AXIS}********************
NO*********HOME - [Homing routine title]************
[NO*********Describe homing routine steps if not obvious**********]
#HOME${AXIS}
IF (home${AXIS}=1)
inhome${AXIS}=1
IF ((home${AXIS}=1) & (hjog${AXIS}=0))
slimfl${AXIS}=_FL${AXIS};FL${AXIS}=2147483647
slimbl${AXIS}=_BL${AXIS};BL${AXIS}=-2147483648
hjog${AXIS}=1
ENDIF
IF ((_LR${AXIS}=0) & (_LF${AXIS}=0) & (home${AXIS}=1))
home${AXIS}=0;MG "home${AXIS}", home${AXIS};ENDIF
IF ((hjog${AXIS}=1) & (_BG${AXIS}=1) & (home${AXIS}=1))
ST${AXIS};ENDIF
[Undertake the appropriate homing steps]
IF ((hjog${AXIS}=[number of homing steps + 1]) & (_BG${AXIS}=0) & (home${AXIS}=1) [& (_SC${AXIS}=10)])
hjog${AXIS}=0;home${AXIS}=0;homed${AXIS}=1
MG "home${AXIS}", home${AXIS};MG "homed${AXIS}", homed${AXIS}
ENDIF
ELSE
hjog${AXIS}=0
ENDIF
IF ((home${AXIS}=0) & (inhome${AXIS}=1))
FL${AXIS}=slimfl${AXIS}
BL${AXIS}=slimbl${AXIS}
inhome${AXIS}=0
ENDIF
IF (mlock=1)
II ,,dpon,dvalues
ENDIF
So for homing step n you would need to follow this basic pattern in the code and update as appropriate, be sure to change the items in square brackets as appropriate, and consider the need or not for a stop code check:
IF ((hjog${AXIS} = n) & (_BG${AXIS}=0) & (home${AXIS}=1) [& (_SC${AXIS}=[value])])
[Homing Routine Step]
hjog${AXIS} = n + 1
ENDIF
The existing steps are detailed in Galil Homing Routine Steps
This is a variation on the above, as it does not include the standard items relating to the soft limits or stopping the motor